» Articles » PMID: 37232880

Amperometric Biosensor for Quantitative Measurement Using Sandwich Immunoassays

Overview
Specialty Biotechnology
Date 2023 May 26
PMID 37232880
Authors
Affiliations
Soon will be listed here.
Abstract

State-of-the-art clinical detection methods typically involve standard immunoassay methods, requiring specialized equipment and trained personnel. This impedes their use in the Point-of-Care (PoC) environment, where ease of operation, portability, and cost efficiency are prioritized. Small, robust electrochemical biosensors provide a means with which to analyze biomarkers in biological fluids in PoC environments. Optimized sensing surfaces, immobilization strategies, and efficient reporter systems are key to improving biosensor detection systems. The signal transduction and general performance of electrochemical sensors are determined by surface properties that link the sensing element to the biological sample. We analyzed the surface characteristics of screen-printed and thin-film electrodes using scanning electron microscopy and atomic force microscopy. An enzyme-linked immunosorbent assay (ELISA) was adapted for use in an electrochemical sensor. The robustness and reproducibility of the developed electrochemical immunosensor were investigated by detecting Neutrophil Gelatinase-Associated Lipocalin (NGAL) in urine. The sensor showed a detection limit of 1 ng/mL, a linear range of 3.5-80 ng/mL, and a CV% of 8%. The results demonstrate that the developed platform technology is suitable for immunoassay-based sensors on either screen-printed or thin-film gold electrodes.

Citing Articles

Sensing the Future-Frontiers in Biosensors: Exploring Classifications, Principles, and Recent Advances.

Manoharan Nair Sudha Kumari S, Thankappan Suryabai X ACS Omega. 2024; 9(50):48918-48987.

PMID: 39713646 PMC: 11656264. DOI: 10.1021/acsomega.4c07991.


Electrochemical Sensors for Antibiotic Detection: A Focused Review with a Brief Overview of Commercial Technologies.

Frigoli M, Krupa M, Hooyberghs G, Lowdon J, Cleij T, Dilien H Sensors (Basel). 2024; 24(17).

PMID: 39275486 PMC: 11398233. DOI: 10.3390/s24175576.


Label-Free Detection of Waterborne Pathogens Using an All-Solid-State Laser-Induced Graphene Potentiometric Ion Flux Immunosensor.

Preechakasedkit P, Pulsrikarn C, Nuanualsuwan S, Rattanadilok Na Phuket N, Citterio D, Ruecha N Anal Chem. 2024; .

PMID: 39263981 PMC: 11428094. DOI: 10.1021/acs.analchem.4c03607.

References
1.
Poghossian A, Schoning M . Capacitive Field-Effect EIS Chemical Sensors and Biosensors: A Status Report. Sensors (Basel). 2020; 20(19). PMC: 7584023. DOI: 10.3390/s20195639. View

2.
Rodriguez A, Burgos-Florez F, Posada J, Cervera E, Zucolotto V, Sanjuan H . Electrochemical Immunosensor for the Quantification of S100B at Clinically Relevant Levels Using a Cysteamine Modified Surface. Sensors (Basel). 2021; 21(6). PMC: 8001999. DOI: 10.3390/s21061929. View

3.
Malla P, Liao H, Liu C, Wu W, Sreearunothai P . Voltammetric biosensor for coronavirus spike protein using magnetic bead and screen-printed electrode for point-of-care diagnostics. Mikrochim Acta. 2022; 189(4):168. PMC: 8973645. DOI: 10.1007/s00604-022-05288-4. View

4.
Wen W, Yan X, Zhu C, Du D, Lin Y . Recent Advances in Electrochemical Immunosensors. Anal Chem. 2017; 89(1):138-156. DOI: 10.1021/acs.analchem.6b04281. View

5.
Araujo G, Fujimura P, Vaz E, Silva T, Rodovalho V, Britto-Madurro A . A novel reactive epitope-based antigen targeted by serum autoantibodies in oligoarticular and polyarticular juvenile idiopathic arthritis and development of an electrochemical biosensor. Immunobiology. 2016; 221(5):634-40. DOI: 10.1016/j.imbio.2016.01.006. View