Evaluation of Three Automated Nontreponemal Rapid Plasma Reagin (RPR) Tests for the Laboratory Diagnosis of Syphilis

Overview
Specialty Microbiology
Date 2023 May 23
PMID 37219422
Authors
Affiliations
Soon will be listed here.
Abstract

Automated nontreponemal rapid plasma reagin (RPR) tests were recently introduced in the United States for syphilis testing and limited performance data are available. In collaboration with the Association of Public Health Laboratories, three public health laboratories (PHL) were chosen through a competitive selection process to evaluate the performance of three FDA-cleared automated RPR test systems: BioPlex 2200 Syphilis Total & RPR assay (Bio-Rad Laboratories), AIX 1000 (Gold Standard Diagnostics), and ASI Evolution (Arlington Scientific). Panels prepared at the CDC included: a qualitative panel comprised of 734 syphilis reactive/nonreactive sera; a quantitative panel of 50 syphilis reactive sera (RPR titer 1:64 to 1:1,024); and a reproducibility panel of 15 nonreactive and reactive sera (RPR titer 1:1 to 1:64). Panels were shipped frozen to the PHL and tested on the automated RPR systems following manufacturers' instructions. Prior test results were blinded to all laboratories. When compared to manual RPR (Arlington Scientific) performed at the CDC as a reference test, the qualitative panel results demonstrated an overall concordance of 95.9% for AIX 1000, 94.6% for ASI Evolution, and 92.6% for Bioplex RPR; quantitative panel showed within range titer of 2-fold for 94% of specimens for AIX 1000, 68% for ASI Evolution, and 64% for BioPlex RPR, and the reproducibility testing panel demonstrated point estimates ranging from 69 to 95%. Automated RPR instruments could reduce turnaround time and minimize interpretation errors. However, additional evaluations with more specimens could assist laboratories with implementing automated RPR tests and understanding their limitations.

Citing Articles

Update on syphilis diagnostics.

Sweitzer S, Duncan J, Sena A Curr Opin Infect Dis. 2024; 38(1):44-53.

PMID: 39641765 PMC: 11695141. DOI: 10.1097/QCO.0000000000001073.


Kinetics of RPR Decline in Pregnant Persons Treated for Syphilis in Pregnancy and Their Infants.

Schwartz D, Tse-Chang A, Robinson J, Gratrix J, Smyczek P, Hawkes M Pathogens. 2024; 13(11).

PMID: 39599563 PMC: 11597520. DOI: 10.3390/pathogens13111010.


Advantages and limitations of current diagnostic laboratory approaches in syphilis and congenital syphilis.

Cao W, Thorpe P, OCallaghan K, Kersh E Expert Rev Anti Infect Ther. 2023; 21(12):1339-1354.

PMID: 37934903 PMC: 10958575. DOI: 10.1080/14787210.2023.2280214.

References
1.
Pedersen N, Orum O, Mouritsen S . Enzyme-linked immunosorbent assay for detection of antibodies to the venereal disease research laboratory (VDRL) antigen in syphilis. J Clin Microbiol. 1987; 25(9):1711-6. PMC: 269313. DOI: 10.1128/jcm.25.9.1711-1716.1987. View

2.
Sanfilippo A, Freeman K, Schmitz J . Comparison of Manual and Fully Automated AIX1000 Rapid Plasma Reagin Assays for Laboratory Diagnosis of Syphilis. J Clin Microbiol. 2018; 56(8). PMC: 6062780. DOI: 10.1128/JCM.00214-18. View

3.
Tang E, Paiva K, Pytel-Parenteau D, Maynard M, Chan P, Lu S . Evaluation of BioPlex 2200 Syphilis Total With Automated Rapid Plasma Reagin: Experience From a Tertiary Medical Center. Sex Transm Dis. 2020; 47(5):301-305. DOI: 10.1097/OLQ.0000000000001153. View

4.
Arbefeville S, Lynch M, Ferrieri P . Evaluation of a Multiplex Fully Automated Treponemal and Nontreponemal (Rapid Plasma Reagin) Assay. Am J Clin Pathol. 2019; 152(2):230-236. DOI: 10.1093/ajcp/aqz034. View

5.
Shukla M, Deutsch J, Pereira L, Kersh E, Fakile Y . Development of a novel magnetic particle-based agglutination immunoassay for anticardiolipin antibody detection in syphilis. Sex Transm Infect. 2020; 96(6):411-416. PMC: 7476289. DOI: 10.1136/sextrans-2020-054437. View