Background: Detecting antibody responses following infection with SARS-CoV-2 is necessary for sero-epidemiological studies and assessing the role of specific antibodies in disease, but serum or plasma sampling is not always viable due to logistical challenges. Dried blood spot sampling (DBS) is a cheaper, simpler alternative and samples can be self-collected and returned by post, reducing risk for SARS-CoV-2 exposure from direct patient contact. The value of large-scale DBS sampling for the assessment of serological responses to SARS-CoV-2 has not been assessed in depth and provides a model for examining the logistics of using this approach to other infectious diseases. The ability to measure specific antigens is attractive for remote outbreak situations where testing may be limited or for patients who require sampling after remote consultation.

Methods: We compared the performance of SARS-CoV-2 anti-spike and anti-nucleocapsid antibody detection from DBS samples with matched serum collected by venepuncture in a large population of asymptomatic young adults (N = 1070) living and working in congregate settings (military recruits, N = 625); university students, N = 445). We also compared the effect of self-sampling (ssDBS) with investigator-collected samples (labDBS) on assay performance, and the quantitative measurement of total IgA, IgG and IgM between DBS eluates and serum.

Results: Baseline seropositivity for anti-spike IgGAM antibody was significantly higher among university students than military recruits. Strong correlations were observed between matched DBS and serum samples in both university students and recruits for the anti-spike IgGAM assay. Minimal differences were found in results by ssDBS and labDBS and serum by Bland Altman and Cohen kappa analyses. LabDBS achieved 82.0% sensitivity and 98.2% specificity and ssDBS samples 86.1% sensitivity and 96.7% specificity for detecting anti-spike IgGAM antibodies relative to serum samples. For anti-SARS-CoV-2 nucleocapsid IgG there was qualitatively 100% agreement between serum and DBS samples and weak correlation in ratio measurements. Strong correlations were observed between serum and DBS-derived total IgG, IgA, and IgM.

Conclusions: This is the largest validation of DBS against paired serum for SARS-CoV-2 specific antibody measurement and we have shown that DBS retains performance from prior smaller studies. There were no significant differences regarding DBS collection methods, suggesting that self-collected samples are a viable sampling collection method. These data offer confidence that DBS can be employed more widely as an alternative to classical serology.

Citing Articles

Health Care Utilisation in a Cohort of Patients with Primary and Secondary Antibody Deficiency in the United Kingdom.

Dimbleby B, Greenway W, Burns S, Richter A, Shields A J Clin Immunol. 2024; 45(1):18.

PMID: 39331196 PMC: 11436396. DOI: 10.1007/s10875-024-01809-3.

References
1.
Parry H, McIlroy G, Bruton R, Ali M, Stephens C, Damery S . Antibody responses after first and second Covid-19 vaccination in patients with chronic lymphocytic leukaemia. Blood Cancer J. 2021; 11(7):136. PMC: 8323747. DOI: 10.1038/s41408-021-00528-x. View

2.
Shields A, Faustini S, Hill H, Al-Taei S, Tanner C, Ashford F . Increased Seroprevalence and Improved Antibody Responses Following Third Primary SARS-CoV-2 Immunisation: An Update From the COV-AD Study. Front Immunol. 2022; 13:912571. PMC: 9201027. DOI: 10.3389/fimmu.2022.912571. View

3.
Vazquez-Moron S, Ardizone Jimenez B, Jimenez-Sousa M, Bellon J, Ryan P, Resino S . Evaluation of the diagnostic accuracy of laboratory-based screening for hepatitis C in dried blood spot samples: A systematic review and meta-analysis. Sci Rep. 2019; 9(1):7316. PMC: 6514168. DOI: 10.1038/s41598-019-41139-8. View

4.
Behets F, Kashamuka M, Pappaioanou M, Green T, Ryder R, Batter V . Stability of human immunodeficiency virus type 1 antibodies in whole blood dried on filter paper and stored under various tropical conditions in Kinshasa, Zaire. J Clin Microbiol. 1992; 30(5):1179-82. PMC: 265246. DOI: 10.1128/jcm.30.5.1179-1182.1992. View

5.
Valentine-Graves M, Hall E, Guest J, Adam E, Valencia R, Shinn K . At-home self-collection of saliva, oropharyngeal swabs and dried blood spots for SARS-CoV-2 diagnosis and serology: Post-collection acceptability of specimen collection process and patient confidence in specimens. PLoS One. 2020; 15(8):e0236775. PMC: 7406082. DOI: 10.1371/journal.pone.0236775. View