» Articles » PMID: 37200325

The Association of Denture Wearing with Reduced Lung Function and Increased Airflow Limitation in 58-72 Year Old Men

Overview
Journal PLoS One
Date 2023 May 18
PMID 37200325
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: To investigate the association between denture wearing and airflow limitation in men in Northern Ireland enrolled in the Prospective Epidemiological Study of Myocardial Infarction (PRIME) study.

Methods: A case-control design was used to study partially dentate men. Cases were men aged 58-72 years who were confirmed as denture wearers. Controls were never denture wearers who were matched by age (± 1 month) and smoking habit to the cases. The men had a periodontal assessment and completed a questionnaire detailing their medical history, dental history and behaviours, social circumstances, demographic background and tobacco use. Physical examination and spirometry measurements of forced expiratory volume in one second (FEV1) and forced vital capacity (FVC) were also undertaken. Spirometry data for edentulous men who wore complete dentures were compared with that recorded for the partially dentate men studied.

Results: There were 353 cases who were partially dentate and were confirmed denture wearers. They were matched for age and smoking habit to never denture wearer controls. The cases had an FEV1 that was on average 140 ml lower than the controls, p = 0.0013 and a 4% reduction in percent predicted FEV1, p = 0.0022. Application of the GOLD criteria indicated that 61 (17.3%) of the cases had moderate to severe airflow limitation compared with 33 (9.3%) of controls, p = 0.0051. Fully adjusted multivariable analysis showed that partially dentate men who were denture wearers were significantly more likely (p = 0.01) to have moderate to severe airflow reduction with an adjusted odds ratio (OR) of 2.37 (95% confidence intervals 1.23-4.55). In the 153 edentulous men studied moderate to severe airflow limitation was recorded in 44 (28.4%), which was significantly higher than in the partially dentate denture wearers (p = 0.017), and the men who had never worn a denture (p<0.0001).

Conclusion: Denture wearing was associated with an increased risk of moderate to severe airflow limitation in the cohort of middle-aged Western European men studied.

Citing Articles

Assessment of lung function in partially edentulous patients using spirometry: A cross-sectional study.

Ayyagari L, Sajjan M, Bhupathi P, Koruprolu R, Alla R J Indian Prosthodont Soc. 2025; 25(1):46-51.

PMID: 39750008 PMC: 11853936. DOI: 10.4103/jips.jips_164_24.

References
1.
Tiew P, Dicker A, Keir H, Poh M, Pang S, Mac Aogain M . A high-risk airway mycobiome is associated with frequent exacerbation and mortality in COPD. Eur Respir J. 2020; 57(3). DOI: 10.1183/13993003.02050-2020. View

2.
Yarnell J . The PRIME study: classical risk factors do not explain the severalfold differences in risk of coronary heart disease between France and Northern Ireland. Prospective Epidemiological Study of Myocardial Infarction. QJM. 1999; 91(10):667-76. DOI: 10.1093/qjmed/91.10.667. View

3.
Gomes-Filho I, Cruz S, Trindade S, Passos-Soares J, Carvalho-Filho P, Figueiredo A . Periodontitis and respiratory diseases: A systematic review with meta-analysis. Oral Dis. 2019; 26(2):439-446. DOI: 10.1111/odi.13228. View

4.
Preshaw P, Walls A, Jakubovics N, Moynihan P, Jepson N, Loewy Z . Association of removable partial denture use with oral and systemic health. J Dent. 2011; 39(11):711-9. DOI: 10.1016/j.jdent.2011.08.018. View

5.
Mayhew D, Devos N, Lambert C, Brown J, Clarke S, Kim V . Longitudinal profiling of the lung microbiome in the AERIS study demonstrates repeatability of bacterial and eosinophilic COPD exacerbations. Thorax. 2018; 73(5):422-430. PMC: 5909767. DOI: 10.1136/thoraxjnl-2017-210408. View