Abstract

Background: Artificial Intelligence (AI) is an area of computer science/engineering that is aiming to spread technological systems. The COVID-19 pandemic caused economic and public health turbulence around the world. Among the many possibilities for using AI in the medical field is FreeStyle Libre (FSL), which uses a disposable sensor inserted into the user's arm, and a touchscreen device/reader is used to scan and retrieve other continuous monitoring of glucose (CMG) readings. The aim of this systematic review is to summarize the effectiveness of FSL blood glucose monitoring during the COVID-19 pandemic.

Methods: This systematic review was carried out in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) and was registered in the international prospective register of systematic reviews (PROSPERO: CRD42022340562). The inclusion criteria considered studies involving the use of the FSL device during the COVID-19 pandemic and published in English. No publication date restrictions were set. The exclusion criteria were abstracts, systematic reviews, studies with patients with other diseases, monitoring with other equipment, patients with COVID-19, and bariatrics patients. Seven databases were searched (PubMed, Scopus, Embase, Web of Science, Scielo, PEDro and Cochrane Library). The ACROBAT-NRSI tool (A Cochrane Risk of Bias Assessment Tool for Non-Randomized Studies) was used to evaluate the risk of bias in the selected articles.

Results: A total of 113 articles were found. Sixty-four were excluded because they were duplicates, 39 were excluded after reading the titles and abstracts, and twenty articles were considered for full reading. Of the 10 articles analyzed, four articles were excluded because they did not meet the inclusion criteria. Thus, six articles were included in the current systematic review. It was observed that among the selected articles, only two were classified as having serious risk of bias. It was shown that FSL had a positive impact on glycemic control and on reducing the number of individuals with hypoglycemia.

Conclusion: The findings suggest that the implementation of FSL during COVID-19 confinement in this population can be confidently stated to have been effective in diabetes mellitus patients.

Citing Articles

Population characteristics, prescription patterns and glycemic control of users of flash glucose monitoring systems in Brazil: a real-world evidence study.

Santo K, Nieri J, Riserio K, Melo K Diabetol Metab Syndr. 2025; 17(1):44.

PMID: 39901274 PMC: 11789284. DOI: 10.1186/s13098-025-01610-1.


Case report: Uncovering hidden glucose patterns in medicated versus unmedicated bipolar disorder and comorbid type 1 diabetes mellitus.

Breznoscakova D, Pallayova M Front Endocrinol (Lausanne). 2024; 15:1354749.

PMID: 38419952 PMC: 10899695. DOI: 10.3389/fendo.2024.1354749.

References
1.
Di Dalmazi G, Maltoni G, Bongiorno C, Tucci L, Di Natale V, Moscatiello S . Comparison of the effects of lockdown due to COVID-19 on glucose patterns among children, adolescents, and adults with type 1 diabetes: CGM study. BMJ Open Diabetes Res Care. 2020; 8(2). PMC: 7594202. DOI: 10.1136/bmjdrc-2020-001664. View

2.
Sonza A, da Cunha de Sa-Caputo D, Sartorio A, Tamini S, Seixas A, Sanudo B . COVID-19 Lockdown and the Behavior Change on Physical Exercise, Pain and Psychological Well-Being: An International Multicentric Study. Int J Environ Res Public Health. 2021; 18(7). PMC: 8038730. DOI: 10.3390/ijerph18073810. View

3.
Ting D, Carin L, Dzau V, Wong T . Digital technology and COVID-19. Nat Med. 2020; 26(4):459-461. PMC: 7100489. DOI: 10.1038/s41591-020-0824-5. View

4.
Elhadd T, Mall R, Bashir M, Palotti J, Fernandez-Luque L, Farooq F . Artificial Intelligence (AI) based machine learning models predict glucose variability and hypoglycaemia risk in patients with type 2 diabetes on a multiple drug regimen who fast during ramadan (The PROFAST - IT Ramadan study). Diabetes Res Clin Pract. 2020; 169:108388. DOI: 10.1016/j.diabres.2020.108388. View

5.
Bonora B, Boscari F, Avogaro A, Bruttomesso D, Fadini G . Glycaemic Control Among People with Type 1 Diabetes During Lockdown for the SARS-CoV-2 Outbreak in Italy. Diabetes Ther. 2020; 11(6):1369-1379. PMC: 7213551. DOI: 10.1007/s13300-020-00829-7. View