This review considers the use of filters to sample air in mining workplace environments for dust concentration measurement and subsequent analysis of hazardous contaminants, especially respirable crystalline silica (RCS) on filters compatible with wearable personal dust monitors (PDM). The review summarizes filter vendors, sizes, costs, chemical and physical properties, and information available on filter modeling, laboratory testing, and field performance. Filter media testing and selection should consider the characteristics required for mass by gravimetry in addition to RCS quantification by Fourier-transform infrared (FTIR) or Raman spectroscopic analysis. For mass determination, the filters need to have high filtration efficiency (≥99% for the most penetrable particle sizes) and a reasonable pressure drop (up to 16.7 kPa) to accommodate high dust loading. Additional requirements include: negligible uptake of water vapor and gaseous volatile compounds; adequate particle adhesion as a function of particle loading; sufficient particle loading capacity to form a stable particle deposit layer during sampling in wet and dusty environments; mechanical strength to withstand vibrations and pressure drops across the filter; and appropriate filter mass compatible with the tapered element oscillating microbalance. FTIR and Raman measurements require filters to be free of spectral interference. Furthermore, because the irradiated area does not completely cover the sample deposit, particles should be uniformly deposited on the filter.

References
1.
Gilbert J, Sartim R, Suringar M, Richards J . Positive bias in particulate matter emissions data due to sulfur dioxide adsorption and oxidation on glass fiber filters. J Air Waste Manag Assoc. 2021; 71(9):1076-1084. DOI: 10.1080/10962247.2021.1902881. View

2.
Breuer D . Flow resistance of samplers for personal monitoring in work areas and requirements for sampling pump performance. J Occup Environ Hyg. 2012; 9(2):D25-32. DOI: 10.1080/15459624.2011.640302. View

3.
Kildeso J, Nielsen B . Exposure assessment of airborne microorganisms by fluorescence microscopy and image processing. Ann Occup Hyg. 1997; 41(2):201-16. DOI: 10.1016/s0003-4878(96)00035-x. View

4.
Lilienfeld P, Dulchinos J . Portable instantaneous mass monitor for coal mine dust. Am Ind Hyg Assoc J. 1972; 33(3):136-45. DOI: 10.1080/0002889728506623. View

5.
SPURNY K . [Membrane filters in aerosology. II. Filtration mechanisms in membrane filters]. Zentralbl Biol Aerosolforsch. 1965; 12(6):530-45. View