» Articles » PMID: 37145976

Project SPRUCE: Saving Our Planet by Reducing Carbon Emissions, a Pediatric Anesthesia Sustainability Quality Improvement Initiative

Overview
Journal Anesth Analg
Specialty Anesthesiology
Date 2023 May 5
PMID 37145976
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Children are particularly vulnerable to adverse health outcomes related to climate change. Inhalational anesthetics are potent greenhouse gasses (GHGs) and contribute significantly to health care-generated emissions. Desflurane and nitrous oxide have very high global warming potentials. Eliminating their use, as well as lowering fresh gas flows (FGFs), will lead to reduced emissions.

Methods: Using published calculations for converting volatile anesthetic concentrations to carbon dioxide equivalents (CO 2 e), we derived the average kilograms (kg) CO 2 e/min for every anesthetic administered in the operating rooms at our pediatric hospital and ambulatory surgical center between October 2017 and October 2022. We leveraged real-world data captured from our electronic medical record systems and used AdaptX to extract and present those data as statistical process control (SPC) charts. We implemented recommended strategies aimed at reducing emissions from inhalational anesthetics, including removing desflurane vaporizers, unplugging nitrous oxide hoses, decreasing the default anesthesia machine FGF, clinical decision support tools, and educational initiatives. Our primary outcome measure was average kg CO 2 e/min.

Results: A combination of educational initiatives, practice constraints, protocol changes, and access to real-world data were associated with an 87% reduction in measured GHG emissions from inhaled anesthesia agents used in the operating rooms over a 5-year period. Shorter cases (<30 minutes duration) had 3 times higher average CO 2 e, likely due to higher FGF and nitrous oxide use associated with inhalational inductions, and higher proportion of mask-only anesthetics. Removing desflurane vaporizers corresponded with a >50% reduction of CO 2 e. A subsequent decrease in anesthesia machine default FGF was associated with a similarly robust emissions reduction. Another significant decrease in emissions was noted with educational efforts, clinical decision support alerts, and feedback from real-time data.

Conclusions: Providing environmentally responsible anesthesia in a pediatric setting is a challenging but achievable goal, and it is imperative to help mitigate the impact of climate change. Large systems changes, such as eliminating desflurane, limiting access to nitrous oxide, and changing default anesthesia machine FGF rates, were associated with rapid and lasting emissions reduction. Measuring and reporting GHG emissions from volatile anesthetics allows practitioners to explore and implement methods of decreasing the environmental impact of their individual anesthesia delivery practices.

Citing Articles

Environmental and patient safety outcomes of a health-system Green Anesthesia Initiative (GAIA): a retrospective observational cohort study.

Colquhoun D, Hovord D, Rachel R, Yuan Y, Mentz G, Koppera P Lancet Planet Health. 2025; 9(2):e124-e133.

PMID: 39986316 PMC: 11881991. DOI: 10.1016/S2542-5196(24)00331-0.


The VITALS Framework: Empowering Programs to Leverage Health Information Technology for Trainee-Led Health Care Decarbonization and Climate Adaptation.

Vedak S, DeTata S, Sarabu C, Leitner S, Outterson R, Li R J Grad Med Educ. 2024; 16(6 Suppl):28-34.

PMID: 39677901 PMC: 11644571. DOI: 10.4300/JGME-D-24-00067.1.


A narrative review of the current available literature on the intersection between the climate crisis and paediatric surgical care.

Patel K, Ossig A, Kudsk-Iversen S Pediatr Surg Int. 2024; 41(1):3.

PMID: 39579176 PMC: 11585486. DOI: 10.1007/s00383-024-05899-3.


Scoping review for the SAGES EAES joint collaborative on sustainability in surgical practice.

Huo B, Eussen M, Marconi S, Johnson S, Francis N, Oslock W Surg Endosc. 2024; 38(10):5483-5504.

PMID: 39174709 PMC: 11458728. DOI: 10.1007/s00464-024-11141-x.


How an Audit-and-Feedback-Based Educational Program Contributed to a Reduction in Environmentally Harmful Waste Anesthetic Gases Among Anesthesiology Residents.

Nordin E, Dugan S, Kusters A, Schimek C, Sherman K, Ebert T J Grad Med Educ. 2024; 16(2):175-181.

PMID: 38993317 PMC: 11234298. DOI: 10.4300/JGME-D-23-00402.1.