Amplification-free Electrochemical Biosensor Detection of Circulating MicroRNA to Identify Drug-induced Liver Injury

Overview
Date 2023 Apr 13
PMID 37054598
Authors
Affiliations
Soon will be listed here.
Abstract

Drug-induced liver injury (DILI) is a major challenge in clinical medicine and drug development. There is a need for rapid diagnostic tests, ideally at point-of-care. MicroRNA 122 (miR-122) is an early biomarker for DILI which is reported to increase in the blood before standard-of-care markers such as alanine aminotransferase activity. We developed an electrochemical biosensor for diagnosis of DILI by detecting miR-122 from clinical samples. We used electrochemical impedance spectroscopy (EIS) for direct, amplification free detection of miR-122 with screen-printed electrodes functionalised with sequence specific peptide nucleic acid (PNA) probes. We studied the probe functionalisation using atomic force microscopy and performed elemental and electrochemical characterisations. To enhance the assay performance and minimise sample volume requirements, we designed and characterised a closed-loop microfluidic system. We presented the EIS assay's specificity for wild-type miR-122 over non-complementary and single nucleotide mismatch targets. We successfully demonstrated a detection limit of 50 pM for miR-122. Assay performance could be extended to real samples; it displayed high selectivity for liver (miR-122 high) comparing to kidney (miR-122 low) derived samples extracted from murine tissue. Finally, we successfully performed an evaluation with 26 clinical samples. Using EIS, DILI patients were distinguished from healthy controls with a ROC-AUC of 0.77, a comparable performance to qPCR detection of miR-122 (ROC-AUC: 0.83). In conclusion, direct, amplification free detection of miR-122 using EIS was achievable at clinically relevant concentrations and in clinical samples. Future work will focus on realising a full sample-to-answer system which can be deployed for point-of-care testing.

Citing Articles

Drug Induced Liver Injury: Highlights and Controversies in the 2023 Literature.

Singh H, Kunkle B, Troia A, Suvarnakar A, Waterman A, Khin Y Drug Saf. 2025; .

PMID: 39921708 DOI: 10.1007/s40264-025-01514-z.


Rapid Detection of microRNA-122 in Serum and Finger Blood Using a Lateral Flow Nucleic Acid Biosensor.

Zhang M, Ma M, Wang J, Zhou Y, Zhang X, Liu G Biosensors (Basel). 2025; 15(1).

PMID: 39852109 PMC: 11764104. DOI: 10.3390/bios15010058.


Flexible Electrochemical Biosensor Using Nanostructure-Modified Polymer Electrode for Detection of Viral Nucleic Acids.

Han J, Lee Y, Lee J, Yoon J Biosensors (Basel). 2024; 14(12).

PMID: 39727860 PMC: 11674301. DOI: 10.3390/bios14120594.


The Evolution of Circulating Biomarkers for Use in Acetaminophen/Paracetamol-Induced Liver Injury in Humans: A Scoping Review.

McGill M, Curry S Livers. 2024; 3(4):569-596.

PMID: 38434489 PMC: 10906739. DOI: 10.3390/livers3040039.