» Articles » PMID: 37050375

Fracture Resistance Analysis of CAD/CAM Interim Fixed Prosthodontic Materials: PMMA, Graphene, Acetal Resin and Polysulfone

Overview
Publisher MDPI
Date 2023 Apr 13
PMID 37050375
Authors
Affiliations
Soon will be listed here.
Abstract

Methods: Four groups of ten samples were fabricated for each material. Each specimen was characterized by a compression test on a universal testing machine, all specimens were loaded to fracture and the value in Newtons (N) was recorded by software connected to the testing machine. The fracture mode was evaluated on all samples using a stereomicroscope.

Results: There were statistically significant differences ( value < 0.005) between PMMA and the other three materials (PMMA: 1302.71 N; GRA: 1990.02 N; RA: 1796.20 N; PS: 2234.97). PMMA presented a significantly lower value than the other materials, and PS showed the highest value. GRA and RA presented a similar range of values but they were still higher than those of PMMA.

Conclusions: GRA, RA and PS are presented as valid options within the range of interim milled restorative materials and as alternatives to PMMA.

Citing Articles

Comparative Study of the Influence of Heat Treatment on Fracture Resistance of Different Ceramic Materials Used for CAD/CAM Systems.

Balladares A, Abad-Coronel C, Ramos J, Fajardo J, Paltan C, Martin Biedma B Materials (Basel). 2024; 17(6).

PMID: 38541399 PMC: 10972524. DOI: 10.3390/ma17061246.


Influence of aging process and restoration thickness on the fracture resistance of provisional crowns: A comparative study.

Alsarani M Saudi Dent J. 2023; 35(8):939-945.

PMID: 38107052 PMC: 10724475. DOI: 10.1016/j.sdentj.2023.07.017.


Can Graphene Pave the Way to Successful Periodontal and Dental Prosthetic Treatments? A Narrative Review.

Apostu A, Sufaru I, Tanculescu O, Stoleriu S, Doloca A, Ciocan Pendefunda A Biomedicines. 2023; 11(9).

PMID: 37760795 PMC: 10525677. DOI: 10.3390/biomedicines11092354.

References
1.
Dubey N, Bentini R, Islam I, Cao T, Castro Neto A, Rosa V . Graphene: A Versatile Carbon-Based Material for Bone Tissue Engineering. Stem Cells Int. 2015; 2015:804213. PMC: 4466492. DOI: 10.1155/2015/804213. View

2.
Ozkan Y, Arikan A, Akalin B, Arda T . A study to assess the colour stability of acetal resins subjected to thermocycling. Eur J Prosthodont Restor Dent. 2005; 13(1):10-4. View

3.
Al-Dwairi Z, Tahboub K, Baba N, Goodacre C, Ozcan M . A Comparison of the Surface Properties of CAD/CAM and Conventional Polymethylmethacrylate (PMMA). J Prosthodont. 2019; 28(4):452-457. DOI: 10.1111/jopr.13033. View

4.
Tortopidis D, Lyons M, Baxendale R, Gilmour W . The variability of bite force measurement between sessions, in different positions within the dental arch. J Oral Rehabil. 1998; 25(9):681-6. DOI: 10.1046/j.1365-2842.1998.00293.x. View

5.
Jiao T, Chang T, Caputo A . Load transfer characteristics of unilateral distal extension removable partial dentures with polyacetal resin supporting components. Aust Dent J. 2009; 54(1):31-7. DOI: 10.1111/j.1834-7819.2008.01085.x. View