» Articles » PMID: 37047124

Direct Electrochemistry of Glucose Dehydrogenase-Functionalized Polymers on a Modified Glassy Carbon Electrode and Its Molecular Recognition of Glucose

Overview
Journal Int J Mol Sci
Publisher MDPI
Date 2023 Apr 13
PMID 37047124
Authors
Affiliations
Soon will be listed here.
Abstract

A glucose biosensor was layer-by-layer assembled on a modified glassy carbon electrode (GCE) from a nanocomposite of NAD(P)-dependent glucose dehydrogenase, aminated polyethylene glycol (mPEG), carboxylic acid-functionalized multi-wall carbon nanotubes (fMWCNTs), and ionic liquid (IL) composite functional polymers. The electrochemical electrode was denoted as NF/IL/GDH/mPEG-fMWCNTs/GCE. The composite polymer membranes were characterized by cyclic voltammetry, ultraviolet-visible spectrophotometry, electrochemical impedance spectroscopy, scanning electron microscopy, and transmission electron microscopy. The cyclic voltammogram of the modified electrode had a pair of well-defined quasi-reversible redox peaks with a formal potential of -61 mV (vs. Ag/AgCl) at a scan rate of 0.05 V s. The heterogeneous electron transfer constant (k) of GDH on the composite functional polymer-modified GCE was 6.5 s. The biosensor could sensitively recognize and detect glucose linearly from 0.8 to 100 µM with a detection limit down to 0.46 μM (S/N = 3) and a sensitivity of 29.1 nA μM. The apparent Michaelis-Menten constant (Kmapp) of the modified electrode was 0.21 mM. The constructed electrochemical sensor was compared with the high-performance liquid chromatography method for the determination of glucose in commercially available glucose injections. The results demonstrated that the sensor was highly accurate and could be used for the rapid and quantitative determination of glucose concentration.

References
1.
Nishioka T, Yasutake Y, Nishiya Y, Tamura T . Structure-guided mutagenesis for the improvement of substrate specificity of Bacillus megaterium glucose 1-dehydrogenase IV. FEBS J. 2012; 279(17):3264-75. DOI: 10.1111/j.1742-4658.2012.08713.x. View

2.
Rahimi P, Rafiee-Pour H, Ghourchian H, Norouzi P, Ganjali M . Ionic-liquid/NH2-MWCNTs as a highly sensitive nano-composite for catalase direct electrochemistry. Biosens Bioelectron. 2009; 25(6):1301-6. DOI: 10.1016/j.bios.2009.10.020. View

3.
Wang C, Li J, Tan R, Wang Q, Zhang Z . Colorimetric method for glucose detection with enhanced signal intensity using ZnFeO-carbon nanotube-glucose oxidase composite material. Analyst. 2019; 144(5):1831-1839. DOI: 10.1039/c8an02330a. View

4.
Kim D, Kim M, Reddy S, Cho J, Cho C, Jung S . Electron-transfer mediator for a NAD-glucose dehydrogenase-based glucose sensor. Anal Chem. 2013; 85(23):11643-9. DOI: 10.1021/ac403217t. View

5.
Ding H, Du Y, Liu D, Li Z, Chen X, Zhao Y . Cloning and expression in E. coli of an organic solvent-tolerant and alkali-resistant glucose 1-dehydrogenase from Lysinibacillus sphaericus G10. Bioresour Technol. 2010; 102(2):1528-36. DOI: 10.1016/j.biortech.2010.08.018. View