» Articles » PMID: 37046515

Single-Site Experience with an Automated Artificial Intelligence Application for Left Ventricular Ejection Fraction Measurement in Echocardiography

Overview
Specialty Radiology
Date 2023 Apr 13
PMID 37046515
Authors
Affiliations
Soon will be listed here.
Abstract

Left ventricular ejection fraction (LVEF) is a key parameter in evaluating left ventricular (LV) function using echocardiography (Echo), but its manual measurement by the modified biplane Simpson (MBS) method is time consuming and operator dependent. We investigated the feasibility of a server-based, commercially available and ready-to use-artificial intelligence (AI) application based on convolutional neural network methods that integrate fully automatic view selection and measurement of LVEF from an entire Echo exam into a single workflow. We prospectively enrolled 1083 consecutive patients who had been referred to Echo for diagnostic or therapeutic purposes. LVEF was measured independently using MBS and AI. Test-retest variability was assessed in 40 patients. The reliability, repeatability, and time efficiency of LVEF measurements were compared between the two methods. Overall, 889 Echos were analyzed by cardiologists with the MBS method and by the AI. Over the study period of 10 weeks, the feasibility of both automatic view classification and seamlessly measured LVEF rose to 81% without user involvement. LVEF, LV end-diastolic and end-systolic volumes correlated strongly between MBS and AI (R = 0.87, 0.89 and 0.93, < 0.001 for all) with a mean bias of +4.5% EF, -12 mL and -11 mL, respectively, due to impaired image quality and the extent of LV function. Repeatability and reliability of LVEF measurement ( = 40, test-retest) by AI was excellent compared to MBS (coefficient of variation: 3.2% vs. 5.9%), although the median analysis time of the AI was longer than that of the operator-dependent MBS method (258 s vs. 171 s). This AI has succeeded in identifying apical LV views and measuring EF in one workflow with comparable results to the MBS method and shows excellent reproducibility. It offers realistic perspectives for fully automated AI-based measurement of LVEF in routine clinical settings.

Citing Articles

An automatic and real-time echocardiography quality scoring system based on deep learning to improve reproducible assessment of left ventricular ejection fraction.

Li X, Liao L, Wu K, Meng A, Jiang Y, Zhu Y Quant Imaging Med Surg. 2025; 15(1):770-785.

PMID: 39839058 PMC: 11744150. DOI: 10.21037/qims-24-512.


The role of artificial intelligence in standardizing global longitudinal strain measurements in echocardiography.

Sveric K, Botan R, Winkler A, Dindane Z, Alothman G, Cansiz B Eur Heart J Imaging Methods Pract. 2024; 2(4):qyae130.

PMID: 39712903 PMC: 11660427. DOI: 10.1093/ehjimp/qyae130.


Segmentation-Free Estimation of Left Ventricular Ejection Fraction Using 3D CNN Is Reliable and Improves as Multiple Cardiac MRI Cine Orientations Are Combined.

Germain P, Labani A, Vardazaryan A, Padoy N, Roy C, Ghannudi S Biomedicines. 2024; 12(10).

PMID: 39457634 PMC: 11505352. DOI: 10.3390/biomedicines12102324.


Transfer Learning Video Classification of Preserved, Mid-Range, and Reduced Left Ventricular Ejection Fraction in Echocardiography.

Decoodt P, Sierra-Sosa D, Anghel L, Cuminetti G, De Keyzer E, Morissens M Diagnostics (Basel). 2024; 14(13).

PMID: 39001328 PMC: 11241427. DOI: 10.3390/diagnostics14131439.

References
1.
Tromp J, Seekings P, Hung C, Iversen M, Frost M, Ouwerkerk W . Automated interpretation of systolic and diastolic function on the echocardiogram: a multicohort study. Lancet Digit Health. 2021; 4(1):e46-e54. DOI: 10.1016/S2589-7500(21)00235-1. View

2.
Asch F, Descamps T, Sarwar R, Karagodin I, Singulane C, Xie M . Human versus Artificial Intelligence-Based Echocardiographic Analysis as a Predictor of Outcomes: An Analysis from the World Alliance Societies of Echocardiography COVID Study. J Am Soc Echocardiogr. 2022; 35(12):1226-1237.e7. PMC: 9293371. DOI: 10.1016/j.echo.2022.07.004. View

3.
Knackstedt C, Bekkers S, Schummers G, Schreckenberg M, Muraru D, Badano L . Fully Automated Versus Standard Tracking of Left Ventricular Ejection Fraction and Longitudinal Strain: The FAST-EFs Multicenter Study. J Am Coll Cardiol. 2015; 66(13):1456-66. DOI: 10.1016/j.jacc.2015.07.052. View

4.
Houard L, Militaru S, Tanaka K, Pasquet A, Vancraeynest D, Vanoverschelde J . Test-retest reliability of left and right ventricular systolic function by new and conventional echocardiographic and cardiac magnetic resonance parameters. Eur Heart J Cardiovasc Imaging. 2020; 22(10):1157-1167. DOI: 10.1093/ehjci/jeaa206. View

5.
Ghorbani A, Ouyang D, Abid A, He B, Chen J, Harrington R . Deep learning interpretation of echocardiograms. NPJ Digit Med. 2020; 3:10. PMC: 6981156. DOI: 10.1038/s41746-019-0216-8. View