» Articles » PMID: 37034247

Experimental Analysis and Numerical Fatigue Life Prediction of 3D-Printed Osteosynthesis Plates

Overview
Date 2023 Apr 10
PMID 37034247
Authors
Affiliations
Soon will be listed here.
Abstract

The trend towards patient-specific medical orthopedic prostheses has led to an increased use of 3D-printed surgical implants made of Ti6Al4V. However, uncertainties arise due to varying printing parameters, particularly with regards to the fatigue limit. This necessitates time-consuming and costly experimental validation before they can be safely used on patients. To address this issue, this study aimed to employ a stress-life fatigue analysis approach coupled with a finite element (FE) simulation to estimate numerically the fatigue limit and location of failure for 3D-printed surgical osteosynthesis plates and to validate the results experimentally. However, predicting the fatigue life of 3D components is not a new concept and has previously been implemented in the medical device field, though without experimental validation. Then, an experimental fatigue test was conducted using a proposed modification to the staircase method introduced in ISO 12107. Additionally, a FE model was developed to estimate the stress cycles on the plate. The stress number of cycles to failure curve (S-N) obtained from the minimum mechanical properties of 3D-printed Ti6AI4V alloy according to ASTM F3001-14 to predict the fatigue limit. The comparison between experimental results and fatigue numerical predictions showed very good agreement. It was found that a linear elastic FE model was sufficient to estimate the fatigue limit, while an elastic-plastic model led to an accurate prediction throughout the implant's cyclic life. The proposed method has great potential for enhancing patient-specific implant designs without the need for time-consuming and costly experimental regulatory testing.

Citing Articles

Bone Plates Runout Prediction Through Tensile Strength and Geometric Properties for Regulatory Mechanical Testing.

Bologna F, Audenino A, Terzini M Ann Biomed Eng. 2023; 52(2):239-249.

PMID: 37726437 PMC: 10810033. DOI: 10.1007/s10439-023-03363-2.

References
1.
Cordey J, Borgeaud M, Perren S . Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone. Injury. 2000; 31 Suppl 3:C21-8. DOI: 10.1016/s0020-1383(00)80028-5. View

2.
Buschang P, Hayasaki H, Throckmorton G . Quantification of human chewing-cycle kinematics. Arch Oral Biol. 2000; 45(6):461-74. DOI: 10.1016/s0003-9969(00)00015-7. View

3.
Peck C . Biomechanics of occlusion--implications for oral rehabilitation. J Oral Rehabil. 2015; 43(3):205-14. DOI: 10.1111/joor.12345. View

4.
He J, Li D, Jiang W, Ke L, Qin G, Ye Y . The Martensitic Transformation and Mechanical Properties of Ti6Al4V Prepared via Selective Laser Melting. Materials (Basel). 2019; 12(2). PMC: 6356939. DOI: 10.3390/ma12020321. View

5.
Ellis E, Throckmorton G . Treatment of mandibular condylar process fractures: biological considerations. J Oral Maxillofac Surg. 2005; 63(1):115-34. DOI: 10.1016/j.joms.2004.02.019. View