Experimental Basis Sets of Quantification of Brain H-Magnetic Resonance Spectroscopy at 3.0 T

Overview
Journal Metabolites
Publisher MDPI
Date 2023 Mar 29
PMID 36984808
Authors
Affiliations
Soon will be listed here.
Abstract

In vivo short echo time (TE) proton magnetic resonance spectroscopy (H-MRS) is a useful method for the quantification of human brain metabolites. The purpose of this study was to evaluate the performance of an in-house, experimentally measured basis set and compare it with the performance of a vendor-provided basis set. A 3T clinical scanner with 32-channel receive-only phased array head coil was used to generate 16 brain metabolites for the metabolite basis set. For voxel localization, point-resolved spin-echo sequence (PRESS) was used with volume of interest (VOI) positioned at the center of the phantoms. Two different basis sets were subjected to linear combination of model spectra of metabolite solutions in vitro (LCModel) analysis to evaluate the in-house acquired in vivo H-MR spectra from the left prefrontal cortex of 22 healthy subjects. To evaluate the performance of the two basis sets, the Cramer-Rao lower bounds (CRLBs) of each basis set were compared. The LCModel quantified the following metabolites and macromolecules: alanine (Ala), aspartate (Asp), γ-amino butyric acid (GABA), glucose (Glc), glutamine (Gln), glutamate (Glu), glutathione (GHS), Ins (myo-Inositol), lactate (Lac), N-acetylaspartate (NAA), N-acetylaspartylglutamate (NAAG), taurine (Tau), phosphoryl-choline + glycerol-phosphoryl-choline (tCho), N-acetylaspartate + N-acetylaspartylglutamate (tNA), creatine + phosphocreatine (tCr), Glu + Gln (Glx) and Lip13a, Lip13b, Lip09, MM09, Lip20, MM20, MM12, MM14, MM17, Lip13a + Lip13b, MM14 + Lip13a + Lip13b + MM12, MM09 + Lip09, MM20 + Lip20. Statistical analysis showed significantly different CRLBs: Asp, GABA, Gln, GSH, Ins, Lac, NAA, NAAG, Tau, tCho, tNA, Glx, MM20, MM20 + Lip20 ( < 0.001), tCr, MM12, MM17 ( < 0.01), and Lip20 ( < 0.05). The estimated ratio of cerebrospinal fluid (CSF) in the region of interest was calculated to be about 5%. Fitting performances are better, for the most part, with the in-house basis set, which is more precise than the vendor-provided basis set. In particular, Asp is expected to have reliable CRLB (<30%) at high field (e.g., 3T) in the left prefrontal cortex of human brain. The quantification of Asp was difficult, due to the inaccuracy of Asp fitting with the vendor-provided basis set.

References
1.
Brambilla P, Stanley J, Sassi R, Nicoletti M, Mallinger A, Keshavan M . 1H MRS study of dorsolateral prefrontal cortex in healthy individuals before and after lithium administration. Neuropsychopharmacology. 2004; 29(10):1918-24. DOI: 10.1038/sj.npp.1300520. View

2.
Wilson M, Davies N, Sun Y, Natarajan K, Arvanitis T, Kauppinen R . A comparison between simulated and experimental basis sets for assessing short-TE in vivo ¹H MRS data at 1.5 T. NMR Biomed. 2010; 23(10):1117-26. DOI: 10.1002/nbm.1538. View

3.
Deelchand D, Adanyeguh I, Emir U, Nguyen T, Valabregue R, Henry P . Two-site reproducibility of cerebellar and brainstem neurochemical profiles with short-echo, single-voxel MRS at 3T. Magn Reson Med. 2014; 73(5):1718-25. PMC: 4272339. DOI: 10.1002/mrm.25295. View

4.
Provencher S . Automatic quantitation of localized in vivo 1H spectra with LCModel. NMR Biomed. 2001; 14(4):260-4. DOI: 10.1002/nbm.698. View

5.
van der Graaf M, Julia-Sape M, Howe F, Ziegler A, Majos C, Moreno-Torres A . MRS quality assessment in a multicentre study on MRS-based classification of brain tumours. NMR Biomed. 2007; 21(2):148-58. DOI: 10.1002/nbm.1172. View