» Articles » PMID: 36979071

An Enhanced 3D Model of Intravascular Lymphatic Valves to Assess Leaflet Apposition and Transvalvular Differences in Wall Distensibility

Overview
Journal Biology (Basel)
Publisher MDPI
Specialty Biology
Date 2023 Mar 29
PMID 36979071
Authors
Affiliations
Soon will be listed here.
Abstract

Lymphatic valves operate in a fluid-dynamically viscous environment that has little in common with that of cardiac valves, and accordingly have a different, axially lengthened, shape. A previously developed 3D fluid/structure interaction model of a lymphatic valve was extended to allow the simulation of stages of valve closure after the leaflets come together. This required that the numerical leaflet be prevented from passing into space occupied by the similar other leaflet. The resulting large deflections of the leaflet and lesser deflections of the rest of the valve were mapped as functions of the transvalvular pressure. In a second new development, the model was reconstructed to allow the vessel wall to have different material properties on either side of where the valve leaflet inserts into the wall. As part of this, a new pre-processing scheme was devised which allows easier construction of models with modified valve dimensions, and techniques for successfully interfacing the CAD software to the FE software are described. A two-fold change in wall properties either side of the leaflet made relatively little difference to valve operation apart from affecting the degree of sinus distension during valve closure. However, the numerically permitted strains were modest (<14%), and did not allow examination of the large-scale highly nonlinear elastic properties exhibited by real lymphatic vessels. A small series of murine popliteal, mesenteric, and inguinal-axillary lymphatic vessel segments containing a valve were experimentally investigated ex vivo. The pressure-diameter curves measured just upstream and just downstream of the valve were parameterised by computing the difference in tubular distensibility at three values of transmural pressure. In the popliteal and mesenteric segments, it was found that the distensibility was usually greater just downstream, i.e., in the sinus region, than upstream, at low and intermediate transmural pressure. However, there was wide variation in the extent of difference, and possible reasons for this are discussed.

Citing Articles

Developmental progression of lymphatic valve morphology and function.

Davis M, Zawieja S, Yang Y Front Cell Dev Biol. 2024; 12:1331291.

PMID: 38450249 PMC: 10915029. DOI: 10.3389/fcell.2024.1331291.


Computational fluid dynamic modeling of the lymphatic system: a review of existing models and future directions.

Jayathungage Don T, Safaei S, Maso Talou G, Russell P, Phillips A, Reynolds H Biomech Model Mechanobiol. 2023; 23(1):3-22.

PMID: 37902894 PMC: 10901951. DOI: 10.1007/s10237-023-01780-9.

References
1.
Reddy N, Krouskop T, Newell Jr P . Biomechanics of a lymphatic vessel. Blood Vessels. 1975; 12(5):261-78. DOI: 10.1159/000158062. View

2.
Venugopal A, Stewart R, Laine G, Dongaonkar R, Quick C . Lymphangion coordination minimally affects mean flow in lymphatic vessels. Am J Physiol Heart Circ Physiol. 2007; 293(2):H1183-9. DOI: 10.1152/ajpheart.01340.2006. View

3.
Wilson J, Edgar L, Prabhakar S, Horner M, van Loon R, Moore Jr J . A fully coupled fluid-structure interaction model of the secondary lymphatic valve. Comput Methods Biomech Biomed Engin. 2018; 21(16):813-823. DOI: 10.1080/10255842.2018.1521964. View

4.
Bertram C, Macaskill C, Moore Jr J . Incorporating measured valve properties into a numerical model of a lymphatic vessel. Comput Methods Biomech Biomed Engin. 2013; 17(14):1519-34. PMC: 4500195. DOI: 10.1080/10255842.2012.753066. View

5.
Lurie F, Kistner R, Eklof B, Kessler D . Mechanism of venous valve closure and role of the valve in circulation: a new concept. J Vasc Surg. 2003; 38(5):955-61. DOI: 10.1016/s0741-5214(03)00711-0. View