Multicenter Evaluation of the Quantra with the QStat Cartridge in Adult Patients Undergoing Liver Transplantation

Overview
Journal Liver Transpl
Date 2023 Mar 28
PMID 36976255
Authors
Affiliations
Soon will be listed here.
Abstract

Blood loss and transfusion of blood products are key concerns during liver transplantation. Whole-blood viscoelastic testing devices have been used to monitor hemostatic function and guide the transfusion of blood products in this patient population. The Quantra System with the QStat Cartridge is a new point-of-care, closed-system viscoelastic testing device that measures changes in clot stiffness during coagulation and fibrinolysis using ultrasound detection of resonance. The aim of this multicenter prospective observational study was to evaluate the Quantra System against the ROTEM delta device in monitoring coagulation and fibrinolysis in patients undergoing liver transplantation. One hundred twenty-five (125) adult subjects (above 18 y old) were enrolled across 5 medical centers in the US. Blood samples were collected at a minimum of 3-time points: preincision (baseline), during the anhepatic phase, and after the start of reperfusion. Performance was assessed as the correlation of equivalent measurements from the QStat Cartridge and ROTEM delta INTEM, EXTEM, and FIBTEM assays. In addition, a clinical concordance analysis was performed to assess the agreement between the 2 devices related to the detection of fibrinolysis. The correlation between the 2 viscoelastic testing devices was strong, with r -values ranging between 0.88 and 0.95, and the overall agreement with respect to detecting fibrinolysis was 90.3% (CI, 86.9%-93.2%). The results indicate that the Quantra with the QStat Cartridge provides comparable information as the ROTEM delta in the assessment of hemostatic function during a liver transplant. Quantra's simplicity of use and availability of rapid results may provide clinicians with a faster, more convenient means to assess coagulation and fibrinolysis status in the operating room and critical care setting.

Citing Articles

Reply to Spiess, B.D.; Houdijk, W.P.M. Comment on "Saner et al. The Yin and the Yang of Hemostasis in End-Stage Liver Disease. 2023, , 5759".

Saner F, Scarlatescu E, Breoring D, Bezinover D J Clin Med. 2024; 13(6).

PMID: 38541893 PMC: 10970883. DOI: 10.3390/jcm13061668.


Comment on Saner et al. The Yin and the Yang of Hemostasis in End-Stage Liver Disease. 2023, , 5759.

Spiess B, Houdijk W J Clin Med. 2024; 13(6).

PMID: 38541891 PMC: 10971401. DOI: 10.3390/jcm13061666.


Sonorheometry Device Thresholds in Liver Transplantation: An Observational Retrospective Study.

Soucy-Proulx M, Kato H, Coeckelenbergh S, Naili Kortaia S, Herboulier L, Pittau G J Clin Med. 2024; 13(3).

PMID: 38337389 PMC: 10856129. DOI: 10.3390/jcm13030696.