» Articles » PMID: 36972119

Proximal Junction Failure in Spine Surgery: Integrating Geometrical and Biomechanical Global Descriptors Improves GAP Score-Based Assessment

Overview
Specialty Orthopedics
Date 2023 Mar 27
PMID 36972119
Authors
Affiliations
Soon will be listed here.
Abstract

Study Design: Retrospective observational study.

Objective: Biomechanical and geometrical descriptors are used to improve global alignment and proportion (GAP) prediction accuracy to detect proximal junctional failure (PJF).

Summary Of Background Data: PJF is probably the most important complication after sagittal imbalance surgery. The GAP score has been introduced as an effective predictor for PJF, but it fails in certain situations. In this study, 112 patient records were gathered (57 PJF; 55 controls) with biomechanical and geometrical descriptors measured to stratify control and failure cases.

Patients And Methods: Biplanar EOS radiographs were used to build 3-dimensional full-spine models and determine spinopelvic sagittal parameters. The bending moment (BM) was calculated as the upper body mass times, the effective distance to the body center of mass at the adjacent upper instrumented vertebra +1. Other geometrical descriptors such as full balance index (FBI), spino-sacral angle (SSA), C7 plumb line/sacrofemoral distance ratio (C7/SFD ratio), T1-pelvic angle (TPA), and cervical inclination angle (CIA) were also evaluated. The respective abilities of the GAP, FBI, SSA, C7/SFD, TPA, CIA, body weight, body mass index, and BM to discriminate PJF cases were analyzed through receiver operating characteristic curves and corresponding areas under the curve (AUC).

Results: GAP (AUC = 0.8816) and FBI (AUC = 0.8933) were able to discriminate PJF cases but the highest discrimination power (AUC = 0.9371) was achieved with BM at upper instrumented vertebra + 1. Parameter cutoff analyses provided quantitative thresholds to characterize the control and failure groups and led to improved PJF discrimination, with GAP and BM being the most important contributors. SSA (AUC = 0.2857), C7/SFD (AUC = 0.3143), TPA (AUC = 0.5714), CIA (AUC = 0.4571), body weight (AUC = 0.6319), and body mass index (AUC = 0.7716) did not adequately predict PJF.

Conclusion: BM reflects the quantitative biomechanical effect of external loads and can improve GAP accuracy. Sagittal alignments and mechanical integrated scores could be used to better prognosticate the risk of PJF.

Citing Articles

Investigation of spinopelvic sagittal alignment and its correlations in asymptomatic pediatric populations.

Qi H, Zhao Z, Zu F, Wang C, Wang C, Zhang Z Sci Rep. 2025; 15(1):6847.

PMID: 40011699 PMC: 11865502. DOI: 10.1038/s41598-025-91481-3.


Proximal Junctional Failure in Adult Spinal Deformity Surgery: An In-depth Review.

Yagi M, Yamanouchi K, Fujita N, Funao H, Ebata S Neurospine. 2023; 20(3):876-889.

PMID: 37798983 PMC: 10562237. DOI: 10.14245/ns.2346566.283.