Design and Validation of a Custom-Made Hyperspectral Microscope Imaging System for Biomedical Applications

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2023 Mar 11
PMID 36904578
Authors
Affiliations
Soon will be listed here.
Abstract

Hyperspectral microscope imaging (HMI) is an emerging modality that integrates spatial information collected by standard laboratory microscopy and the spectral-based contrast obtained by hyperspectral imaging and may be instrumental in establishing novel quantitative diagnostic methodologies, particularly in histopathology. Further expansion of HMI capabilities hinges upon the modularity and versatility of systems and their proper standardization. In this report, we describe the design, calibration, characterization, and validation of the custom-made laboratory HMI system based on a Zeiss Axiotron fully motorized microscope and a custom-developed Czerny-Turner-type monochromator. For these important steps, we rely on a previously designed calibration protocol. Validation of the system demonstrates a performance comparable to classic spectrometry laboratory systems. We further demonstrate validation against a laboratory hyperspectral imaging system for macroscopic samples, enabling future comparison of spectral imaging results across length scales. An example of the utility of our custom-made HMI system on a standard hematoxylin and eosin-stained histology slide is also shown.

Citing Articles

Systematic Meta-Analysis of Computer-Aided Detection of Breast Cancer Using Hyperspectral Imaging.

Leung J, Karmakar R, Mukundan A, Thongsit P, Chen M, Chang W Bioengineering (Basel). 2024; 11(11).

PMID: 39593720 PMC: 11591395. DOI: 10.3390/bioengineering11111060.


Effects of phantom microstructure on their optical properties.

Stergar J, Hren R, Milanic M J Biomed Opt. 2024; 29(9):093502.

PMID: 38715718 PMC: 11070965. DOI: 10.1117/1.JBO.29.9.093502.


Hyperspectral Imaging with Active Illumination: A Theoretical Study on the Use of Incandescent Lamp and Variable Filament Temperature.

Simoncic U, Milanic M Sensors (Basel). 2023; 23(23).

PMID: 38067699 PMC: 10708585. DOI: 10.3390/s23239326.

References
1.
Tani S, Fukunaga Y, Shimizu S, Fukunishi M, Ishii K, Tamiya K . Color standardization method and system for whole slide imaging based on spectral sensing. Anal Cell Pathol (Amst). 2011; 35(2):107-15. PMC: 4605804. DOI: 10.3233/ACP-2011-0037. View

2.
Ortega S, Fabelo H, Camacho R, Plaza M, Callico G, Sarmiento R . Detecting brain tumor in pathological slides using hyperspectral imaging. Biomed Opt Express. 2018; 9(2):818-831. PMC: 5854081. DOI: 10.1364/BOE.9.000818. View

3.
Leavesley S, Jiang Y, Patsekin V, Rajwa B, Robinson J . An excitation wavelength-scanning spectral imaging system for preclinical imaging. Rev Sci Instrum. 2008; 79(2 Pt 1):023707. DOI: 10.1063/1.2885043. View

4.
Khouj Y, Dawson J, Coad J, Vona-Davis L . Hyperspectral Imaging and K-Means Classification for Histologic Evaluation of Ductal Carcinoma . Front Oncol. 2018; 8:17. PMC: 5808285. DOI: 10.3389/fonc.2018.00017. View

5.
Edelstein A, Tsuchida M, Amodaj N, Pinkard H, Vale R, Stuurman N . Advanced methods of microscope control using μManager software. J Biol Methods. 2015; 1(2). PMC: 4297649. DOI: 10.14440/jbm.2014.36. View