» Articles » PMID: 36867471

Rotational Stability of Plate-haptic Toric Intraocular Lenses in Asian Eyes: Risk Period for Intraocular Lens Rotation and Its Influencing Factors

Overview
Specialty Ophthalmology
Date 2023 Mar 3
PMID 36867471
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate the rotational stability of plate-haptic toric intraocular lenses (IOLs) during 3-month follow-up.

Setting: Eye and ENT Hospital of Fudan University, Shanghai, China.

Design: Prospective observational study.

Methods: Patients with cataracts implanted with AT TORBI 709M toric IOLs were enrolled and followed at 1 hour, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was applied to investigate the time course of absolute IOL rotation change. The 2-week overall IOL rotation was analyzed in the age, sex, axial length (AL), lens thickness (LT), preexisting astigmatism, and white-to-white subgroups.

Results: A total of 328 eyes of 258 patients were included. The rotation from the end of surgery to 1 hour and 1 day to 3 days was significantly smaller compared with the rotation from 1 hour to 1 day but more than that at other time intervals in the overall group. 2 weeks postoperatively, the mean uncorrected distance visual acuity and remaining positive cylinder were 0.19 ± 0.22 logMAR and 0.60 ± 0.44 diopters, respectively. Significant between-group differences in 2-week overall rotation were found in the age, AL, and LT subgroups.

Conclusions: Maximum rotation occurred within 1 hour to 1 day postoperatively, and the first 3 days postoperatively was a high-risk period for the plate-haptic toric IOL rotation. Surgeons should make the patients aware of this.

Citing Articles

Clinical Results of a Monofocal Aspheric Bitoric Intraocular Lens with Plate Haptics in Hyperopic Eyes.

Tana-Rivero P, Munoz-Tomas J, Orts-Vila P, Artiaga-Elordi E, Pastor-Pascual F, Marin-Sanchez J Clin Ophthalmol. 2024; 18:1933-1944.

PMID: 38983598 PMC: 11231029. DOI: 10.2147/OPTH.S467523.


Insights into the rotational stability of toric intraocular lens implantation: diagnostic approaches, influencing factors and intervention strategies.

Lin X, Ma D, Yang J Front Med (Lausanne). 2024; 11:1349496.

PMID: 38414624 PMC: 10896894. DOI: 10.3389/fmed.2024.1349496.


Rotational stability of monofocal and diffractive multifocal toric intraocular lens with identical design and material: a propensity score based prospective comparative study.

Shi R, Ma D, Zeng Q, Hua Z, Shen W, Cai L BMC Ophthalmol. 2024; 24(1):72.

PMID: 38365667 PMC: 10870427. DOI: 10.1186/s12886-024-03281-4.