Clinical Validation of a Contactless Respiration Rate Monitor

Overview
Journal Sci Rep
Specialty Science
Date 2023 Mar 1
PMID 36859403
Authors
Affiliations
Soon will be listed here.
Abstract

Respiratory rate (RR) is an often underestimated and underreported vital sign with tremendous clinical value. As a predictor of cardiopulmonary arrest, chronic obstructive pulmonary disease (COPD) exacerbation or indicator of health state for example in COVID-19 patients, respiratory rate could be especially valuable in remote long-term patient monitoring, which is challenging to implement. Contactless devices for home use aim to overcome these challenges. In this study, the contactless Sleepiz One+ respiration monitor for home use during sleep was validated against the thoracic effort belt. The agreement of instantaneous breathing rate and breathing rate statistics between the Sleepiz One+ device and the thoracic effort belt was initially evaluated during a 20-min sleep window under controlled conditions (no body movement) on a cohort of 19 participants and secondly in a more natural setting (uncontrolled for body movement) during a whole night on a cohort of 139 participants. Excellent agreement was shown for instantaneous breathing rate to be within 3 breaths per minute (Brpm) compared to thoracic effort band with an accuracy of 100% and mean absolute error (MAE) of 0.39 Brpm for the setting controlled for movement, and an accuracy of 99.5% with a MAE of 0.48 Brpm for the whole night measurement, respectively. Excellent agreement was also achieved for the respiratory rate statistics over the whole night with absolute errors of 0.43, 0.39 and 0.67 Brpm for the 10th, 50th and 90th percentiles, respectively. Based on these results we conclude that the Sleepiz One+ can estimate instantaneous respiratory rate and its summary statistics at high accuracy in a clinical setting. Further studies are required to evaluate the performance in the home environment, however, it is expected that the performance is at similar level, as the measurement conditions for the Sleepiz One+ device are better at home than in a clinical setting.

Citing Articles

Smart furniture using radar technology for cardiac health monitoring.

Gharamohammadi A, Bagheri M, Abu-Sardanah S, Riad M, Abedi H, Ansariyan A Sci Rep. 2025; 15(1):1392.

PMID: 39789002 PMC: 11718008. DOI: 10.1038/s41598-024-80062-5.


Validation and user experience of a dry electrode based Health Patch for heart rate and respiration rate monitoring.

Wei J, van den Broek T, van Baardewijk J, van Stokkum R, Kamstra R, Rikken L Sci Rep. 2024; 14(1):23098.

PMID: 39367187 PMC: 11452725. DOI: 10.1038/s41598-024-73557-8.


Feasibility study of the use of a wearable vital sign patch in an intensive care unit setting.

Stevens G, Larmuseau M, Van Damme A, Vanoverschelde H, Heerman J, Verdonck P J Clin Monit Comput. 2024; 39(1):245-256.

PMID: 39158782 DOI: 10.1007/s10877-024-01207-5.


A Guide to Measuring Heart and Respiratory Rates Based on Off-the-Shelf Photoplethysmographic Hardware and Open-Source Software.

Stevens G, Hantson L, Larmuseau M, Heerman J, Siau V, Verdonck P Sensors (Basel). 2024; 24(12).

PMID: 38931550 PMC: 11207213. DOI: 10.3390/s24123766.


Validation of the Sleepiz One + as a radar-based sensor for contactless diagnosis of sleep apnea.

Gross-Isselmann J, Eggert T, Wildenauer A, Dietz-Terjung S, Grosse Sundrup M, Schoebel C Sleep Breath. 2024; 28(4):1691-1699.

PMID: 38744804 PMC: 11303430. DOI: 10.1007/s11325-024-03057-6.


References
1.
Wedzicha J, Seemungal T . COPD exacerbations: defining their cause and prevention. Lancet. 2007; 370(9589):786-96. PMC: 7134993. DOI: 10.1016/S0140-6736(07)61382-8. View

2.
. Prevalence and attributable health burden of chronic respiratory diseases, 1990-2017: a systematic analysis for the Global Burden of Disease Study 2017. Lancet Respir Med. 2020; 8(6):585-596. PMC: 7284317. DOI: 10.1016/S2213-2600(20)30105-3. View

3.
Vinh Phuc Tran , Al-Jumaily A . Non-contact dual pulse Doppler system based respiratory and heart rates estimation for CHF patients. Annu Int Conf IEEE Eng Med Biol Soc. 2016; 2015:4202-5. DOI: 10.1109/EMBC.2015.7319321. View

4.
Gu C . Short-Range Noncontact Sensors for Healthcare and Other Emerging Applications: A Review. Sensors (Basel). 2016; 16(8). PMC: 5017335. DOI: 10.3390/s16081169. View

5.
Lauteslager T, Maslik M, Siddiqui F, Marfani S, Leschziner G, Williams A . Validation of a New Contactless and Continuous Respiratory Rate Monitoring Device Based on Ultra-Wideband Radar Technology. Sensors (Basel). 2021; 21(12). PMC: 8230718. DOI: 10.3390/s21124027. View