» Articles » PMID: 36837438

Robotic-Assisted Total Knee Arthroplasty Utilizing NAVIO, CORI Imageless Systems and Manual TKA Accurately Restore Femoral Rotational Alignment and Yield Satisfactory Clinical Outcomes: A Randomized Controlled Trial

Overview
Publisher MDPI
Specialty General Medicine
Date 2023 Feb 25
PMID 36837438
Authors
Affiliations
Soon will be listed here.
Abstract

: The introduction of novel techniques in total knee arthroplasty (TKA) aiming to enhance outcomes and satisfaction of the procedure is constantly ongoing. In order to evidence a priority of one, we have conducted a randomized controlled trial with the aim of comparing patient-reported functional outcomes, radiographic outcomes and intraoperative measures between imageless (NAVIO and CORI), robotic-assisted (ra)- TKA (ra-TKA) and manual TKA (mTKA) for primary knee osteoarthritis (KOA). : A total of 215 patients with the diagnosis of KOA of the knee were randomly assigned to one of the three groups: NAVIO (76 patients) or CORI (71 patients) robotic-assisted TKA, or manual technique (68 patients) TKA. The primary outcome (Knee Injury and Osteoarthritis Outcome Study [KOOS]), Visual Analogue Scale (VAS), Range of motion (ROM), femoral component rotational alignment and the secondary outcomes (surgery time, blood loss, complications, and revision at 12 months after surgery) were compared between three groups. KOOS and VAS were collected at particular follow up visits from each patient individually and ROM in flexion and extension was assessed during the physical examination. Femoral component rotational alignment was measured on the CT scan performed postoperatively utilizing the Berger's method. Statistical significance was set at < 0.05. : Both the ra-TKA groups and mTKA group displayed significant improvements in the majority of the functional outcome scores at 12 months. Despite having more prominent surgery time (NAVIO: mean +44.5 min in comparison to mTKA and CORI: mean +38.5 min in comparison to mTKA), both NAVIO and CORI tend to achieve highly accurate femoral component rotational alignment with mean radiographic scores in NAVIO vs. CORI vs. mTKA of 1.48° vs. 1.33° vs. 3.15° and lower blood loss (NAVIO: 1.74; CORI: 1.51; mTKA: 2.32. Furthermore, the investigation revealed the significant difference in femoral component rotational alignment between mTKA-NAVIO and mTKA-CORI and significantly different KOOS scores in NAVIO vs. CORI vs. mTKA of 87.05 vs. 85.59 vs. 81.76. Furthermore, the KOOS analysis showed between group significant statistical differences, but did not reach minimal clinically significant difference. There were no differences in postoperative ROM and VAS. There were no differences in complications between groups. : To achieve a successful TKA, the precise tool and individualised objective is of great importance. The results suggest satisfactory results after both ra-TKA methods and mTKA. Ra-TKA and mTKA stand for a safe and reliable treatment method for OA. Patients reported excellent alleviation in functional outcomes and the radiological results revealed that the better precision does not necessarily lead to a better outcome. Therefore, ra-TKA does not imply strong enough advantages in comparison to the manual method, especially in terms of cost-efficiency and surgical time.

Citing Articles

Orthopedic surgical robotic systems in knee arthroplasty: a comprehensive review.

Fan X, Wang Y, Zhang S, Xing Y, Li J, Ma X Front Bioeng Biotechnol. 2025; 13:1523631.

PMID: 40051834 PMC: 11882601. DOI: 10.3389/fbioe.2025.1523631.


Accuracy and learning curve of imageless robotic-assisted total knee arthroplasty.

Bosco F, Rovere G, Burgio C, Lo Bue G, Cobisi C, Giai Via R J Orthop. 2025; 66:77-83.

PMID: 39896862 PMC: 11779652. DOI: 10.1016/j.jor.2024.12.029.


[Early effectiveness of navigation-free robot-assisted total knee arthroplasty in treating knee osteoarthritis with extra-articular deformities].

Meng C, Xu Y, Shi R, Pu L, Ji J, Yao X Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2025; 39(1):5-12.

PMID: 39848709 PMC: 11757961. DOI: 10.7507/1002-1892.202408061.


Computer-aided robotics for applications in fracture reduction surgery: Advances, challenges, and opportunities.

Zhou X, Chen Y, Miao G, Guo Y, Zhang Q, Bi J iScience. 2025; 28(1):111509.

PMID: 39811638 PMC: 11732504. DOI: 10.1016/j.isci.2024.111509.


Comparison of the efficacy of robot-assisted total knee arthroplasty in patients with knee osteoarthritis with varying severity deformity.

Xing P, Qu J, Feng S, Guo J, Huang T J Orthop Surg Res. 2024; 19(1):872.

PMID: 39719605 PMC: 11668079. DOI: 10.1186/s13018-024-05372-w.


References
1.
Delanois R, Mistry J, Gwam C, Mohamed N, Choksi U, Mont M . Current Epidemiology of Revision Total Knee Arthroplasty in the United States. J Arthroplasty. 2017; 32(9):2663-2668. DOI: 10.1016/j.arth.2017.03.066. View

2.
Robertson E, Hengherr M, Amsler F, Hirschmann M, Mathis D . A comparison of femoral component rotation after total knee arthroplasty in Kanekasu radiographs, axial CT slices and 3D reconstructed images. Skeletal Radiol. 2021; 50(7):1389-1397. PMC: 8119264. DOI: 10.1007/s00256-020-03702-7. View

3.
Onggo J, Onggo J, de Steiger R, Hau R . Robotic-assisted total knee arthroplasty is comparable to conventional total knee arthroplasty: a meta-analysis and systematic review. Arch Orthop Trauma Surg. 2020; 140(10):1533-1549. DOI: 10.1007/s00402-020-03512-5. View

4.
Clement N, Al-Zibari M, Afzal I, Deehan D, Kader D . A systematic review of imageless hand-held robotic-assisted knee arthroplasty: learning curve, accuracy, functional outcome and survivorship. EFORT Open Rev. 2020; 5(5):319-326. PMC: 7265084. DOI: 10.1302/2058-5241.5.190065. View

5.
Batailler C, White N, Ranaldi F, Neyret P, Servien E, Lustig S . Improved implant position and lower revision rate with robotic-assisted unicompartmental knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. 2018; 27(4):1232-1240. DOI: 10.1007/s00167-018-5081-5. View