Reliability of a Custom Device Used to Measure Isometric Knee Flexor and Extensor Strength in Standing Position

Overview
Journal Life (Basel)
Specialty Biology
Date 2023 Feb 25
PMID 36836815
Authors
Affiliations
Soon will be listed here.
Abstract

Assessing lower limb strength in the field is problematic, as the "gold standard assessment" with isokinetic strength is cumbersome, and the device is costly and not transportable and keeps the angle of the hip at around 90°. : We evaluated isometric muscle strength in a standing position with the help of an exoskeleton that holds the subject and makes the test easily repeatable. The optimal device angles for hip and knee were, respectively, 20° and 80° for flexor tests and 30° and 40° for extensor tests. Test-retest reliability was very high for the right knee extensor (ICC 0.96-0.98), left knee extensor (ICC 0.96-0.97), right knee flexor (ICC 0.91-0.96), and left knee flexor (ICC 0.96-0.97). Furthermore, the typical error in percent (T.E.%) ranged from 2.50 to 5.50%, and the change in the mean in percent ranged from 0.84 to 7.72%, making it possible to determine even a slight variation in force. this new method could represent a valid alternative for assessing strength, due to the high reliability and the favorable joint position, particularly in football.

Citing Articles

Application of a Custom Device to Measure Isometric Knee Strength: Possible Injury Correlation in Professional Soccer (Football) Players.

Cigni P, Minuti T, Mannini A, Cucini A, Costagli M, Rapetti S J Funct Morphol Kinesiol. 2023; 8(4).

PMID: 37873900 PMC: 10594464. DOI: 10.3390/jfmk8040141.

References
1.
Mondin D, Owen J, Negro M, DAntona G . Validity and Reliability of a Non-invasive Test to Assess Quadriceps and Hamstrings Strength in Athletes. Front Physiol. 2018; 9:1702. PMC: 6281997. DOI: 10.3389/fphys.2018.01702. View

2.
Malorgio A, Malorgio M, Benedetti M, Casarosa S, Cannataro R . High intensity resistance training as intervention method to knee osteoarthritis. Sports Med Health Sci. 2022; 3(1):46-48. PMC: 9219264. DOI: 10.1016/j.smhs.2021.02.005. View

3.
Sung K, Yi Y, Shin H . Reliability and validity of knee extensor strength measurements using a portable dynamometer anchoring system in a supine position. BMC Musculoskelet Disord. 2019; 20(1):320. PMC: 6615264. DOI: 10.1186/s12891-019-2703-0. View

4.
Lord J, Aitkens S, McCrory M, BERNAUER E . Isometric and isokinetic measurement of hamstring and quadriceps strength. Arch Phys Med Rehabil. 1992; 73(4):324-30. DOI: 10.1016/0003-9993(92)90004-g. View

5.
Tomko P, Colquhoun R, Banks N, Magrini M, Muddle T, Jenkins N . Maximal contraction methods influence the magnitude and reliability of global electromyographic signal characteristics. J Electromyogr Kinesiol. 2019; 48:121-127. DOI: 10.1016/j.jelekin.2019.07.002. View