» Articles » PMID: 36831496

Dosimetric Impact of Intrafraction Prostate Motion and Interfraction Anatomical Changes in Dose-Escalated Linac-Based SBRT

Overview
Journal Cancers (Basel)
Publisher MDPI
Specialty Oncology
Date 2023 Feb 25
PMID 36831496
Authors
Affiliations
Soon will be listed here.
Abstract

The dosimetric impact of intrafraction prostate motion and interfraction anatomical changes and the effect of beam gating and motion correction were investigated in dose-escalated linac-based SBRT. Fifty-six gated fractions were delivered using a novel electromagnetic tracking device with a 2 mm threshold. Real-time prostate motion data were incorporated into the patient's original plan with an isocenter shift method. Delivered dose distributions were obtained by recalculating these motion-encoded plans on deformed CTs reflecting the patient's CBCT daily anatomy. Non-gated treatments were simulated using the prostate motion data assuming that no treatment interruptions have occurred. The mean relative dose differences between delivered and planned treatments were -3.0% [-18.5-2.8] for CTV D99% and -2.6% [-17.8-1.0] for PTV D95%. The median cumulative CTV coverage with 93% of the prescribed dose was satisfactory. Urethra sparing was slightly degraded, with the maximum dose increased by only 1.0% on average, and a mean reduction in the rectum and bladder doses was seen in almost all dose metrics. Intrafraction prostate motion marginally contributed in gated treatments, while in non-gated treatments, further deteriorations in the minimum target coverage and bladder dose metrics would have occurred on average. The implemented motion management strategy and the strict patient preparation regimen, along with other treatment optimization strategies, ensured no significant degradations of dose metrics in delivered treatments.

Citing Articles

Treatment accuracy of standard linear accelerator-based prostate SBRT: the delivered dose assessment of patients treated within two major clinical trials using an in-house position monitoring system.

Arumugam S, Young T, Jones C, Pryor D, Sidhom M Front Oncol. 2024; 14:1372968.

PMID: 39184052 PMC: 11341385. DOI: 10.3389/fonc.2024.1372968.


Stereotactic body radiation therapy (SBRT) for prostate cancer: Improving treatment delivery efficiency and accuracy.

Mastella E, Epile J, De Guglielmo E, Fabbri S, Calderoni F, Manco L Tech Innov Patient Support Radiat Oncol. 2024; 30:100253.

PMID: 38746647 PMC: 11090872. DOI: 10.1016/j.tipsro.2024.100253.


Treatment Optimization in Linac-Based SBRT for Localized Prostate Cancer: A Single-Arc versus Dual-Arc Plan Comparison.

Panizza D, Faccenda V, Arcangeli S, De Ponti E Cancers (Basel). 2024; 16(1).

PMID: 38201441 PMC: 10778084. DOI: 10.3390/cancers16010013.


Planning CT Identifies Patients at Risk of High Prostate Intrafraction Motion.

Ballhausen H, Li M, Lombardo E, Landry G, Belka C Cancers (Basel). 2023; 15(16).

PMID: 37627131 PMC: 10452220. DOI: 10.3390/cancers15164103.


Assessment of intrafraction motion and its dosimetric impact on prostate radiotherapy using an in-house developed position monitoring system.

Arumugam S, Young T, Do V, Chlap P, Tawfik C, Udovitch M Front Oncol. 2023; 13:1082391.

PMID: 37519787 PMC: 10375704. DOI: 10.3389/fonc.2023.1082391.


References
1.
Litzenberg D, Hadley S, Tyagi N, Balter J, Ten Haken R, Chetty I . Synchronized dynamic dose reconstruction. Med Phys. 2007; 34(1):91-102. DOI: 10.1118/1.2388157. View

2.
Ballhausen H, Li M, Hegemann N, Ganswindt U, Belka C . Intra-fraction motion of the prostate is a random walk. Phys Med Biol. 2014; 60(2):549-63. DOI: 10.1088/0031-9155/60/2/549. View

3.
Azcona J, Xing L, Chen X, Bush K, Li R . Assessing the dosimetric impact of real-time prostate motion during volumetric modulated arc therapy. Int J Radiat Oncol Biol Phys. 2014; 88(5):1167-74. PMC: 4088267. DOI: 10.1016/j.ijrobp.2013.12.015. View

4.
Varadhan R, Hui S, Way S, Nisi K . Assessing prostate, bladder and rectal doses during image guided radiation therapy--need for plan adaptation?. J Appl Clin Med Phys. 2009; 10(3):56-74. PMC: 5720560. DOI: 10.1120/jacmp.v10i3.2883. View

5.
Pearson D, Gill S, Campbell N, Reddy K . Dosimetric and volumetric changes in the rectum and bladder in patients receiving CBCT-guided prostate IMRT: analysis based on daily CBCT dose calculation. J Appl Clin Med Phys. 2016; 17(6):107-117. PMC: 5690499. DOI: 10.1120/jacmp.v17i6.6207. View