» Articles » PMID: 36829743

Identification of Coronary Artery Diseases Using Photoplethysmography Signals and Practical Feature Selection Process

Overview
Date 2023 Feb 25
PMID 36829743
Authors
Affiliations
Soon will be listed here.
Abstract

A low-cost, fast, dependable, repeatable, non-invasive, portable, and simple-to-use vascular screening tool for coronary artery diseases (CADs) is preferred. Photoplethysmography (PPG), a low-cost optical pulse wave technology, is one method with this potential. PPG signals come from changes in the amount of blood in the microvascular bed of tissue. Therefore, these signals can be used to figure out anomalies within the cardiovascular system. This work shows how to use PPG signals and feature selection-based classifiers to identify cardiorespiratory disorders based on the extraction of time-domain features. Data were collected from 360 healthy and cardiovascular disease patients. For analysis and identification, five types of cardiovascular disorders were considered. The categories of cardiovascular diseases were identified using a two-stage classification process. The first stage was utilized to differentiate between healthy and unhealthy subjects. Subjects who were found to be abnormal were then entered into the second stage classifier, which was used to determine the type of the disease. Seven different classifiers were employed to classify the dataset. Based on the subset of features found by the classifier, the Naïve Bayes classifier obtained the best test accuracy, with 94.44% for the first stage and 89.37% for the second stage. The results of this study show how vital the PPG signal is. Many time-domain parts of the PPG signal can be easily extracted and analyzed to find out if there are problems with the heart. The results were accurate and precise enough that they did not need to be looked at or analyzed further. The PPG classifier built on a simple microcontroller will work better than more expensive ones and will not make the patient nervous.

Citing Articles

WF-PPG: A Wrist-finger Dual-Channel Dataset for Studying the Impact of Contact Pressure on PPG Morphology.

Ho M, Pham H, Saeed A, Ma D Sci Data. 2025; 12(1):200.

PMID: 39900957 PMC: 11790827. DOI: 10.1038/s41597-025-04453-7.


Accelerating antimicrobial peptide design: Leveraging deep learning for rapid discovery.

Al-Omari A, Akkam Y, Zyout A, Younis S, Tawalbeh S, Al-Sawalmeh K PLoS One. 2024; 19(12):e0315477.

PMID: 39705302 PMC: 11661626. DOI: 10.1371/journal.pone.0315477.


Development of a novel light-sensitive PPG model using PPG scalograms and PPG-NET learning for non-invasive hypertension monitoring.

Al Fahoum A, Al Omari A, Al Omari G, Zyout A Heliyon. 2024; 10(21):e39745.

PMID: 39524813 PMC: 11546445. DOI: 10.1016/j.heliyon.2024.e39745.


Leveraging Classifier Performance Using Heuristic Optimization for Detecting Cardiovascular Disease from PPG Signals.

Palanisamy S, Rajaguru H Diagnostics (Basel). 2024; 14(20).

PMID: 39451610 PMC: 11507182. DOI: 10.3390/diagnostics14202287.


DDLA: a double deep latent autoencoder for diabetic retinopathy diagnose based on continuous glucose sensors.

Tao R, Li H, Lu J, Huang Y, Wang Y, Lu W Med Biol Eng Comput. 2024; 62(10):3089-3106.

PMID: 38775870 DOI: 10.1007/s11517-024-03120-0.


References
1.
Al-Fahoum A, Al-Fraihat A, Al-Araida A . Detection of cardiac ischaemia using bispectral analysis approach. J Med Eng Technol. 2014; 38(6):311-6. DOI: 10.3109/03091902.2014.925983. View

2.
Jain P, Tiwari A . Heart monitoring systems--a review. Comput Biol Med. 2014; 54:1-13. DOI: 10.1016/j.compbiomed.2014.08.014. View

3.
Clair C, Rigotti N, Porneala B, Fox C, DAgostino R, Pencina M . Association of smoking cessation and weight change with cardiovascular disease among adults with and without diabetes. JAMA. 2013; 309(10):1014-21. PMC: 3791107. DOI: 10.1001/jama.2013.1644. View

4.
Pilt K, Ferenets R, Meigas K, Lindberg L, Temitski K, Viigimaa M . New photoplethysmographic signal analysis algorithm for arterial stiffness estimation. ScientificWorldJournal. 2013; 2013:169035. PMC: 3747602. DOI: 10.1155/2013/169035. View

5.
Awad A, Haddadin A, Tantawy H, Badr T, Stout R, Silverman D . The relationship between the photoplethysmographic waveform and systemic vascular resistance. J Clin Monit Comput. 2007; 21(6):365-72. DOI: 10.1007/s10877-007-9097-5. View