» Articles » PMID: 36816277

OCTOPUS - Optical Coherence Tomography Plaque and Stent Analysis Software

Overview
Journal Heliyon
Specialty Social Sciences
Date 2023 Feb 23
PMID 36816277
Authors
Affiliations
Soon will be listed here.
Abstract

Background And Objective: Compared with other imaging modalities, intravascular optical coherence tomography (IVOCT) has significant advantages for guiding percutaneous coronary interventions, assessing their outcomes, and characterizing plaque components. To aid IVOCT research studies, we developed the Optical Coherence TOmography PlaqUe and Stent (OCTOPUS) analysis software, which provides highly automated, comprehensive analysis of coronary plaques and stents in IVOCT images.

Methods: User specifications for OCTOPUS were obtained from detailed, iterative discussions with IVOCT analysts in the Cardiovascular Imaging Core Laboratory at University Hospitals Cleveland Medical Center, a leading laboratory for IVOCT image analysis. To automate image analysis results, the software includes several important algorithmic steps: pre-processing, deep learning plaque segmentation, machine learning identification of stent struts, and registration of pullbacks for sequential comparisons. Intuitive, interactive visualization and manual editing of segmentations were included in the software. Quantifications include stent deployment characteristics (e.g., stent area and stent strut malapposition), strut level analysis, calcium angle, and calcium thickness measurements. Interactive visualizations include () anatomical, en face, and longitudinal views with optional overlays (e.g., segmented calcifications). To compare images over time, linked visualizations were enabled to display up to four registered vessel segments at a time.

Results: OCTOPUS has been deployed for nearly 1 year and is currently being used in multiple IVOCT studies. Underlying plaque segmentation algorithm yielded excellent pixel-wise results (86.2% sensitivity and 0.781 F1 score). Using OCTOPUS on 34 new pullbacks, we determined that following automated segmentation, only 13% and 23% of frames needed any manual touch up for detailed lumen and calcification labeling, respectively. Only up to 3.8% of plaque pixels were modified, leading to an average editing time of only 7.5 s/frame, an approximately 80% reduction compared to manual analysis. Regarding stent analysis, sensitivity and precision were both greater than 90%, and each strut was successfully classified as either covered or uncovered with high sensitivity (94%) and specificity (90%). We demonstrated use cases for sequential analysis. To analyze plaque progression, we loaded multiple pullbacks acquired at different points (e.g., pre-stent, 3-month follow-up, and 18-month follow-up) and evaluated frame-level development of in-stent neo-atherosclerosis. In ex vivo cadaver experiments, the OCTOPUS software enabled visualization and quantitative evaluation of irregular stent deployment in the presence of calcifications identified in pre-stent images.

Conclusions: We introduced and evaluated the clinical application of a highly automated software package, OCTOPUS, for quantitative plaque and stent analysis in IVOCT images. The software is currently used as an offline tool for research purposes; however, the software's embedded algorithms may also be useful for real-time treatment planning.

Citing Articles

Artificial Intelligence in Imaging for Personalized Management of Coronary Artery Disease.

Bednarek A, Gumiezna K, Barus P, Kochman J, Tomaniak M J Clin Med. 2025; 14(2).

PMID: 39860467 PMC: 11765647. DOI: 10.3390/jcm14020462.


Evaluating the Influence of Morphological Features on the Vulnerability of Lipid-Rich Plaques During Stenting.

Colmenarez J, Dong P, Lee J, Wilson D, Gu L J Biomech Eng. 2024; 147(2.

PMID: 39665787 PMC: 11748963. DOI: 10.1115/1.4067398.


Deep-learning-driven optical coherence tomography analysis for cardiovascular outcome prediction in patients with acute coronary syndrome.

Hamana T, Nishimori M, Shibata S, Kawamori H, Toba T, Hiromasa T Eur Heart J Digit Health. 2024; 5(6):692-701.

PMID: 39563910 PMC: 11570387. DOI: 10.1093/ehjdh/ztae067.


Plaque Characteristics Derived from Intravascular Optical Coherence Tomography That Predict Cardiovascular Death.

Lee J, Gharaibeh Y, Zimin V, Kim J, Hassani N, Dallan L Bioengineering (Basel). 2024; 11(8).

PMID: 39199801 PMC: 11351967. DOI: 10.3390/bioengineering11080843.


Deep learning segmentation of fibrous cap in intravascular optical coherence tomography images.

Lee J, Kim J, Dallan L, Zimin V, Hoori A, Hassani N Sci Rep. 2024; 14(1):4393.

PMID: 38388637 PMC: 10884035. DOI: 10.1038/s41598-024-55120-7.


References
1.
Lee J, Gharaibeh Y, Kolluru C, Zimin V, Dallan L, Kim J . Segmentation of Coronary Calcified Plaque in Intravascular OCT Images Using a Two-Step Deep Learning Approach. IEEE Access. 2021; 8:225581-225593. PMC: 7885992. DOI: 10.1109/access.2020.3045285. View

2.
Guagliumi G, Costa M, Sirbu V, Musumeci G, Bezerra H, Suzuki N . Strut coverage and late malapposition with paclitaxel-eluting stents compared with bare metal stents in acute myocardial infarction: optical coherence tomography substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute.... Circulation. 2011; 123(3):274-81. DOI: 10.1161/CIRCULATIONAHA.110.963181. View

3.
Lu H, Gargesha M, Wang Z, Chamie D, Attizzani G, Kanaya T . Automatic stent detection in intravascular OCT images using bagged decision trees. Biomed Opt Express. 2012; 3(11):2809-24. PMC: 3493217. DOI: 10.1364/BOE.3.002809. View

4.
Pfisterer M, Rocca H, Buser P, Rickenbacher P, Hunziker P, Mueller C . Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol. 2006; 48(12):2584-91. DOI: 10.1016/j.jacc.2006.10.026. View

5.
Sinclair H, Bourantas C, Bagnall A, Mintz G, Kunadian V . OCT for the identification of vulnerable plaque in acute coronary syndrome. JACC Cardiovasc Imaging. 2015; 8(2):198-209. DOI: 10.1016/j.jcmg.2014.12.005. View