Continuous, Real-time, Noninvasive Monitor of Blood Pressure: Penaz Methodology Applied to the Finger

Overview
Journal J Clin Monit
Specialty Biotechnology
Date 1987 Oct 1
PMID 3681362
Citations 31
Authors
Affiliations
Soon will be listed here.
Abstract

The finger blood pressure monitor measures blood pressure continuously and noninvasively by means of a technique described by J. Penaz. The size of the artery is measured when its internal pressure (arterial pressure) equals the external pressure. (At this point, transmural pressure equals zero and the arterial wall is said to be "unloaded.") This unloaded condition is maintained by continuous, automatic adjustments of external pressure on the artery, adjustments that are made simultaneously with and parallel to intraarterial pressure variations. The external pressure then constantly equals internal pressure (arterial blood pressure) and is reported by the monitor as values for systolic, mean, and diastolic pressure. A finger cuff with a built-in light source and detector is used to measure finger artery size, and an inflatable bladder is used to apply the external pressure to the artery. The monitor is microprocessor based; algorithms determine the unloaded artery size approximately every minute and automatically correct for changes possibly induced by smooth muscle contraction or relaxation, and a high-speed electropneumatic servo control system enables automatic calibration and adjustment.

Citing Articles

Respiratory Event-Induced Blood Pressure Oscillations Vary by Sleep Stage in Sleep Apnea Patients.

Chaung Y, Alex R, Jani M, Watenpaugh D, Vilimkova Kahankova R, Sands S Sleep Disord. 2023; 2023:8787132.

PMID: 37360853 PMC: 10287529. DOI: 10.1155/2023/8787132.


Validating cuffless continuous blood pressure monitoring devices.

Hu J, Martin G, Iyengar S, Kovell L, Plante T, van Helmond N Cardiovasc Digit Health J. 2023; 4(1):9-20.

PMID: 36865583 PMC: 9971997. DOI: 10.1016/j.cvdhj.2023.01.001.


Low-frequency component of photoplethysmogram reflects the autonomic control of blood pressure.

Karavaev A, Borovik A, Borovkova E, Orlova E, Simonyan M, Ponomarenko V Biophys J. 2021; 120(13):2657-2664.

PMID: 34087217 PMC: 8390904. DOI: 10.1016/j.bpj.2021.05.020.


Development of a Multi-Array Pressure Sensor Module for Radial Artery Pulse Wave Measurement.

Roh D, Han S, Park J, Shin H Sensors (Basel). 2019; 20(1).

PMID: 31861569 PMC: 6983064. DOI: 10.3390/s20010033.


Cerebrovascular reactivity during the Valsalva maneuver in migraine, tension-type headache and medication overuse headache.

Wallasch T, Beckmann P, Kropp P Funct Neurol. 2012; 26(4):223-7.

PMID: 22364943 PMC: 3814561.


References
1.
Gravenstein J, Paulus D, Feldman J, McLaughlin G . Tissue hypoxia distal to a Peñaz finger blood pressure cuff. J Clin Monit. 1985; 1(2):120-5. DOI: 10.1007/BF02832199. View

2.
Smith N, Wesseling K, de Wit B . Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger. J Clin Monit. 1985; 1(1):17-29. DOI: 10.1007/BF02832685. View

3.
Langewouters G, Zwart A, Busse R, Wesseling K . Pressure-diameter relationships of segments of human finger arteries. Clin Phys Physiol Meas. 1986; 7(1):43-56. DOI: 10.1088/0143-0815/7/1/003. View

4.
Wesseling K, Settels J, van der Hoeven G, Nijboer J, Butijn M, DORLAS J . Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger. Cardiovasc Res. 1985; 19(3):139-45. DOI: 10.1093/cvr/19.3.139. View

5.
Hirai M, Nielsen S, Lassen N . Blood pressure measurement of all five fingers by strain gauge plethysmography. Scand J Clin Lab Invest. 1976; 36(7):627-32. DOI: 10.1080/00365517609054487. View