» Articles » PMID: 36792853

Detection of the Glenoid Bare Spot by Non-arthrographic MR Imaging, Conventional MR Arthrography, and 3D High-resolution T1-weighted VIBE MR Arthrography: Comparison with CT Arthrography

Overview
Journal Eur Radiol
Specialty Radiology
Date 2023 Feb 15
PMID 36792853
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: To determine the diagnostic accuracy of non-arthrographic MR imaging, conventional MR arthrography, and 3D T1-weighted volumetric interpolated breath-hold examination (VIBE) MR arthrography sequences as compared with a CT arthrography in the diagnosis of glenoid bare spot.

Methods: A retrospective study of 216 patients who underwent non-arthrographic MR imaging, conventional MR arthrography, VIBE MRI arthrography, and CT arthrogram between January 2011 and March 2022 was conducted. The diagnostic accuracy of non-arthrographic MR imaging, direct MR arthrography, and VIBE MRI arthrography in the detection of glenoid bare spot was compared with that of CT arthrography. All studies were reviewed by 2 MSK radiologists. Interobserver agreement for MR imaging and MR arthrographic findings was calculated.

Results: Sixteen of 216 patients were excluded. Twenty-three of 200 shoulders had glenoid bare spot on CT arthrographic images. The glenoid bare spot was detected in 11 (47.8%) and 7 (30.4%) patients on conventional non-arthrographic MR images and in 18 (78.3%) and 16 (69.6%) patients on conventional MR arthrograms by observers 1 and 2, respectively. Both observers separately described the bare spot in 22 of 23 patients (95.7%) on 3D volumetric MR arthrograms. Interobserver variabilities were fair agreement for conventional non-arthrographic MR imaging (κ = 0.35, p < 0.05), moderate agreement for conventional MR arthrogram (κ = 0.50, p < 0.05), and near-perfect agreement for 3D volumetric MR arthrogram reading (κ = 0.87, p < 0.05).

Conclusions: A 3D high-resolution T1-weighted VIBE MR arthrography sequence may yield diagnostic performance that is comparable with that of CT arthrography in the diagnosis of glenoid bare spot.

Key Points: •Glenoid bare spot should not be misdiagnosed as a transchondral defect of the glenoid surface by radiologists. •A 3D high-resolution T1-weighted VIBE MR arthrography sequence may be used as a high-sensitivity imaging technique in the diagnosis of glenoid bare spot.

Citing Articles

Comparison of conventional MR arthrography and 3D volumetric MR arthrography in detection of cartilage defects accompanying glenoid labrum pathologies.

Gokce A, Guclu D, Unlu E, Kazoglu I, Arican M, Ogul H Skeletal Radiol. 2023; 53(6):1081-1090.

PMID: 38051423 DOI: 10.1007/s00256-023-04536-9.

References
1.
Dunham K, Bencardino J, Rokito A . Anatomic variants and pitfalls of the labrum, glenoid cartilage, and glenohumeral ligaments. Magn Reson Imaging Clin N Am. 2012; 20(2):213-28, x. DOI: 10.1016/j.mric.2012.01.014. View

2.
Burkhart S, DeBeer J, Tehrany A, Parten P . Quantifying glenoid bone loss arthroscopically in shoulder instability. Arthroscopy. 2002; 18(5):488-91. DOI: 10.1053/jars.2002.32212. View

3.
Kralinger F, Aigner F, Longato S, Rieger M, Wambacher M . Is the bare spot a consistent landmark for shoulder arthroscopy? A study of 20 embalmed glenoids with 3-dimensional computed tomographic reconstruction. Arthroscopy. 2006; 22(4):428-32. DOI: 10.1016/j.arthro.2005.12.006. View

4.
Chuang T, Adams C, Burkhart S . Use of preoperative three-dimensional computed tomography to quantify glenoid bone loss in shoulder instability. Arthroscopy. 2008; 24(4):376-82. DOI: 10.1016/j.arthro.2007.10.008. View

5.
Pearce McCarty 3rd L, Cole B . Nonarthroplasty treatment of glenohumeral cartilage lesions. Arthroscopy. 2005; 21(9):1131-42. DOI: 10.1016/j.arthro.2005.06.023. View