Extended Use of an Open-Source Automated Insulin Delivery System in Children and Adults with Type 1 Diabetes: The 24-Week Continuation Phase Following the CREATE Randomized Controlled Trial
Overview
Authors
Affiliations
To assess long-term efficacy and safety of open-source automated insulin delivery (AID) in children and adults (7-70 years) with type 1 diabetes. Both arms of a 24-week randomized controlled trial comparing open-source AID (OpenAPS algorithm within a modified version of AndroidAPS, preproduction DANA-i™ insulin pump, Dexcom G6 continuous glucose monitor) with sensor-augmented pump therapy (SAPT), entered a 24-week continuation phase where the SAPT arm (termed SAPT-AID) crossed over to join the open-source AID arm (termed AID-AID). Most participants (69/94) used a preproduction YpsoPump insulin pump during the continuation phase. Analyses incorporated all 52 weeks of data, and combined between-group and within-subject differences to calculate an overall "treatment effect" of AID versus SAPT. Mean time in range (TIR; 3.9-10 mmol/L [70-180 mg/dL]) was 12.2% higher with AID than SAPT (95% confidence interval [CI] 10.4 to 14.1; < 0.001). TIR was 56.9% (95% CI 54.2 to 59.6) with SAPT and 69.1% (95% CI 67.1 to 71.1) with AID. The treatment effect did not differ by age ( = 0.39) or insulin pump type ( = 0.37). HbA1c was 5.1 mmol/mol lower [0.5%] with AID (95% CI -6.6 to -3.6; < 0.001). There were no episodes of diabetic ketoacidosis or severe hypoglycemia with either treatment over the 48 weeks. Six participants (all in SAPT-AID) withdrew: three with hardware issues, two preferred SAPT, and one with infusion-site skin irritation. Further evaluation of the community derived automated insulin delivery (CREATE) trial to 48 weeks confirms that open-source AID is efficacious and safe with different insulin pumps, and demonstrates sustained glycemic improvements without additional safety concerns.
Biester T, Berget C, Boughton C, Cudizio L, Ekhlaspour L, Hilliard M Horm Res Paediatr. 2024; 97(6):636-662.
PMID: 39657603 PMC: 11854989. DOI: 10.1159/000543034.
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes-2025.
Diabetes Care. 2024; 48(Supplement_1):S181-S206.
PMID: 39651989 PMC: 11635045. DOI: 10.2337/dc25-S009.
Kietaibl A, Schutz-Fuhrmann I, Bozkurt L, Fruhwald L, Rami-Merhar B, Frohlich-Reiterer E Wien Klin Wochenschr. 2024; 136(Suppl 9):467-477.
PMID: 39196351 PMC: 11358222. DOI: 10.1007/s00508-024-02400-x.
von Kobyletzki L, Ulriksdotter J, von Kobyletzki E, Mowitz M, Jendle J, Svedman C J Diabetes Sci Technol. 2024; 18(6):1300-1312.
PMID: 38853748 PMC: 11535278. DOI: 10.1177/19322968241252613.
Automated Insulin Delivery Systems in Pediatric Type 1 Diabetes: A Narrative Review.
Adolfsson P, Hanas R, Zaharieva D, Dovc K, Jendle J J Diabetes Sci Technol. 2024; 18(6):1324-1333.
PMID: 38785359 PMC: 11535396. DOI: 10.1177/19322968241248404.