» Articles » PMID: 36732725

Bionic Reconstruction of Tension Trabeculae in Short-stem Hip Arthroplasty: a Finite Element Analysis

Overview
Publisher Biomed Central
Specialties Orthopedics
Physiology
Date 2023 Feb 2
PMID 36732725
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Short-stem hip arthroplasty (SHA) is characterized by metaphyseal load transfer that effectively preserves the bone stock, but still suffers from stress shielding in the proximal femur. We designed a tension screw to mimic tension trabeculae in the new bionic collum femoris preserving (BCFP) short stem for bionic reconstruction, aiming to restore the biomechanics of hip joint.

Methods: Native femur finite element model was constructed to investigate the biomechanics of hip joint based on computed tomography (CT) data. The maximum absolute principal stress/strain cloud chart allowed the direction of stress/strain to be assessed. Six BCFP models with different screw angles (5°, 10°, 15°, 20°, 25°, and 30°) and the Corail model were created. The stress/strain distribution and overall stiffness were compared between each of the BCFP and Corail implanted models.

Results: The native model visualized the transfer pathways of tensile and compressive stress. The BCFP stems showed significantly higher stress and strain distribution in the greater trochanteric region compared to conventional total hip arthroplasty (THA). In particular, the BCFP-5° stem demonstrated the highest average strain in both medial and lateral regions and the overall stiffness was closest to the intact femur.

Conclusions: Stress transfer pathways of trabecular architecture provide biomechanical insight that serves as the basis for bionic reconstruction. The tension screw improves load transfer pattern in the proximal femur and prevents stress reduction in the greater trochanteric region. The BCFP-5° stem minimizes the stress shielding effect and presents a more bionic mechanical performance.

Citing Articles

Regional distribution of microvasculature within the canine femoral head: a study of plastinated tissue histology and 3D reconstruction.

Alam Shah M, Tang W, Ma Y, Zhe W, Yu S, Sui H J Orthop Surg Res. 2025; 20(1):170.

PMID: 39962538 PMC: 11834394. DOI: 10.1186/s13018-025-05522-8.


Finite Element Analysis of Proximal Femoral Bionic Nail (PFBN), Proximal Femoral Nail Antirotation and InterTan for Treatment of Reverse Obliquity Intertrochanteric Fractures.

Xiong C, Zhang L, Wang Y, Zhang X, Chen X, Yu K Orthop Surg. 2025; 17(3):888-899.

PMID: 39865505 PMC: 11872354. DOI: 10.1111/os.14345.

References
1.
Bieger R, Ignatius A, Reichel H, Durselen L . Biomechanics of a short stem: In vitro primary stability and stress shielding of a conservative cementless hip stem. J Orthop Res. 2013; 31(8):1180-6. DOI: 10.1002/jor.22349. View

2.
Stolk J, Verdonschot N, Huiskes R . Hip-joint and abductor-muscle forces adequately represent in vivo loading of a cemented total hip reconstruction. J Biomech. 2001; 34(7):917-26. DOI: 10.1016/s0021-9290(00)00225-6. View

3.
Sumner D . Long-term implant fixation and stress-shielding in total hip replacement. J Biomech. 2015; 48(5):797-800. DOI: 10.1016/j.jbiomech.2014.12.021. View

4.
van Loon J, Vervest A, van der Vis H, Sierevelt I, Baas D, Opdam K . Ceramic-on-ceramic articulation in press-fit total hip arthroplasty as a potential reason for early failure, what about the survivors: a ten year follow-up. Int Orthop. 2021; 45(6):1447-1454. PMC: 8178149. DOI: 10.1007/s00264-020-04895-1. View

5.
Stulberg S, Patel R . The short stem: promises and pitfalls. Bone Joint J. 2013; 95-B(11 Suppl A):57-62. DOI: 10.1302/0301-620X.95B11.32936. View