» Articles » PMID: 36723833

A Comparison of Vessel Patch Materials in Tetralogy of Fallot Patients Using Virtual Surgery Techniques

Overview
Journal Ann Biomed Eng
Date 2023 Feb 1
PMID 36723833
Authors
Affiliations
Soon will be listed here.
Abstract

Tetralogy of Fallot (ToF) is characterized by stenosis causing partial obstruction of the right ventricular outflow tract, typically alleviated through the surgical application of a vessel patch made from a biocompatible material. In this study, we use computational simulations to compare the mechanical performance of four patch materials for various stenosis locations. Nine idealized pre-operative ToF geometries were created by imposing symmetrical stenoses on each of three anatomical sub-regions of the pulmonary arteries of three patients with previously repaired ToF. A virtual surgery methodology was implemented to replicate the steps of vessel de-pressurization, surgical patching, and subsequent vessel expansion after reperfusion. Significant differences in patch average stress (p < 0.001) were found between patch materials. Biological patch materials (porcine xenopericardium, human pericardium) exhibited higher patch stresses in comparison to synthetic patch materials (Dacron and PTFE). Observed differences were consistent across the various stenosis locations and were insensitive to patient anatomy.

Citing Articles

New Tissue-Engineered Vascular Matrix Based on Regenerated Silk Fibroin: Study.

Prokudina E, Senokosova E, Antonova L, Krivkina E, Velikanova E, Akentieva T Sovrem Tekhnologii Med. 2024; 15(4):41-48.

PMID: 38434192 PMC: 10902900. DOI: 10.17691/stm2023.15.4.04.

References
1.
Antiga L, Piccinelli M, Botti L, Ene-Iordache B, Remuzzi A, Steinman D . An image-based modeling framework for patient-specific computational hemodynamics. Med Biol Eng Comput. 2008; 46(11):1097-112. DOI: 10.1007/s11517-008-0420-1. View

2.
Apitz C, Webb G, Redington A . Tetralogy of Fallot. Lancet. 2009; 374(9699):1462-71. DOI: 10.1016/S0140-6736(09)60657-7. View

3.
Boumpouli M, Sauvage E, Capelli C, Schievano S, Kazakidi A . Characterization of Flow Dynamics in the Pulmonary Bifurcation of Patients With Repaired Tetralogy of Fallot: A Computational Approach. Front Cardiovasc Med. 2021; 8:703717. PMC: 8514754. DOI: 10.3389/fcvm.2021.703717. View

4.
Bustos C, Garcia-Herrera C, Celentano D . Mechanical characterisation of Dacron graft: Experiments and numerical simulation. J Biomech. 2015; 49(1):13-18. DOI: 10.1016/j.jbiomech.2015.11.014. View

5.
Chen C, Chen J, Wu W, Shi Y, Jin L, Petrini L . In vivo and in vitro evaluation of a biodegradable magnesium vascular stent designed by shape optimization strategy. Biomaterials. 2019; 221:119414. PMC: 6732791. DOI: 10.1016/j.biomaterials.2019.119414. View