» Articles » PMID: 36700021

Continuous Cement Leakage Along the Posterior Longitudinal Ligament of the Intraspinal Epidural During a Percutaneous Vesselplasty: A Case Report and Literature Review

Overview
Journal Front Surg
Specialty General Surgery
Date 2023 Jan 26
PMID 36700021
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: This study aims to report one case of intraspinal epidural cement leakage caused by a novel percutaneous vesselplasty.

Methods: A clinical case report from the Orthopedic center of our hospital and a literature review. A 63-year-old woman with an L osteoporotic compression fracture underwent novel kyphoplasty, percutaneous vesselplasty. This rare complication was evaluated through a literature search, and its special types are classified in more detail.

Results: The patient was hospitalized with low back pain two weeks after a fall. After auxiliary examination, a new type of percutaneous vesselplasty was performed. After the intraoperative injection of bone cement, bone cement leakage extended along the posterior longitudinal ligament and epidural space. There were no special compression symptoms of the spinal cord, and the prognosis of conservative treatment was good.

Conclusion: Although percutaneous vesselplasty is relatively safe and frequent, intraspinal leakage may occur, so sufficient preoperative evaluation, intraoperative continuous fluoroscopic monitoring, and timely evaluation of postoperative images are extremely necessary.

References
1.
Lu Q, Gao S, Zhou M . The effect of bone cement on the curative effect of percutaneous kyphoplasty in the treatment of osteoporotic vertebral compression fracture. Ann Palliat Med. 2021; 10(10):11013-11023. DOI: 10.21037/apm-21-2767. View

2.
Tang B, Xu S, Chen X, Cui L, Wang Y, Yan X . The impact of intravertebral cleft on cement leakage in percutaneous vertebroplasty for osteoporotic vertebral compression fractures: a case-control study. BMC Musculoskelet Disord. 2021; 22(1):805. PMC: 8449924. DOI: 10.1186/s12891-021-04685-9. View

3.
Buchbinder R, Johnston R, Rischin K, Homik J, Jones C, Golmohammadi K . Percutaneous vertebroplasty for osteoporotic vertebral compression fracture. Cochrane Database Syst Rev. 2018; 4:CD006349. PMC: 6494647. DOI: 10.1002/14651858.CD006349.pub3. View

4.
Li J, Yuan X, Li F, Ding Y, Ma G, Song C . A randomized trial comparing the clinical efficacy and safety of a novel steerable percutaneous kyphoplasty with traditional PKP in osteoporotic vertebral fractures. Ann Transl Med. 2021; 9(12):1024. PMC: 8267321. DOI: 10.21037/atm-21-1880. View

5.