Our study objects to determine the diagnostic accuracy of two-dimensional speckle tracking echocardiography (2DSTE) in predicting presence and severity of coronary artery disease (CAD). Patients with stable angina pectoris with normal left ventricular function (>50%) undergoing coronary angiography were enrolled and subjected to speckle tracking echocardiography. Global longitudinal peak systolic strain was measured and correlated to the results of coronary angiography for each patient. Number of male (=0.001), diabetes (=0.01) and smoking (=0.01) patients were significantly higher in the CAD group compared to non-CAD patients. Global longitudinal peak systolic strain (GLPSS) was significantly (=0.0001) lower in CAD patients in comparison to non- CAD patients. GLPSS showed significantly lower in patients with Syntax score (SS)≥22 in comparison to SS<22. Cut-off value -19 for GLPSS could be used to predict the presence of significant CAD with 80.6% sensitivity and 76.5% specificity (area under curve (AUC) -0.83, =0.0001). The mean GLPSS value decreased as the number of diseased coronary vessels increased (=0.0001). The optimal cut-off value of -16 GLPSS with a sensitivity of 76.7% and specificity of 83.3% [AUC 0.84, <0.0001] was found significant to predict CAD severity. Multivariate regression of GLPSS and another risk factor for predicting significant CAD, GLPSS showed OR=1.55 (CI-1.36-1.76) =0.0001 for predicting the presence of CAD. 2DSTE can be used as a non-invasive screening test in predicting presence, extent and severity of significant CAD patients with suspected stable angina pectoris.

Citing Articles

Resting segmental speckle tracking strain and strain rate in stable coronary artery disease and revascularized myocardial infarction.

Caglayan H, Kjonas D, Kornev M, Iqbal A, Jazbani M, Rosner A Int J Cardiovasc Imaging. 2024; 40(10):2077-2086.

PMID: 39179715 PMC: 11499336. DOI: 10.1007/s10554-024-03200-0.


The clinical value of noninvasive left ventricular myocardial work in the diagnosis of myocardial ischemia in coronary heart disease: a comparative study with coronary flow reserve fraction.

Zhao Y, He F, Guo W, Ge Z, Ge Z, Lu Y Int J Cardiovasc Imaging. 2024; 40(10):2167-2179.

PMID: 39096407 DOI: 10.1007/s10554-024-03208-6.

References
1.
Winter R, Jussila R, Nowak J, Brodin L . Speckle tracking echocardiography is a sensitive tool for the detection of myocardial ischemia: a pilot study from the catheterization laboratory during percutaneous coronary intervention. J Am Soc Echocardiogr. 2007; 20(8):974-81. DOI: 10.1016/j.echo.2007.01.029. View

2.
Gaibazzi N, Pigazzani F, Reverberi C, Porter T . Rest global longitudinal 2D strain to detect coronary artery disease in patients undergoing stress echocardiography: a comparison with wall-motion and coronary flow reserve responses. Echo Res Pract. 2015; 1(2):61-70. PMC: 4676453. DOI: 10.1530/ERP-14-0020. View

3.
Sjoli B, Orn S, Grenne B, Ihlen H, Edvardsen T, Brunvand H . Diagnostic capability and reproducibility of strain by Doppler and by speckle tracking in patients with acute myocardial infarction. JACC Cardiovasc Imaging. 2009; 2(1):24-33. DOI: 10.1016/j.jcmg.2008.10.007. View

4.
Biering-Sorensen T, Hoffmann S, Mogelvang R, Iversen A, Galatius S, Fritz-Hansen T . Myocardial strain analysis by 2-dimensional speckle tracking echocardiography improves diagnostics of coronary artery stenosis in stable angina pectoris. Circ Cardiovasc Imaging. 2013; 7(1):58-65. DOI: 10.1161/CIRCIMAGING.113.000989. View

5.
Hoit B . Strain and strain rate echocardiography and coronary artery disease. Circ Cardiovasc Imaging. 2011; 4(2):179-90. DOI: 10.1161/CIRCIMAGING.110.959817. View