» Articles » PMID: 36695791

EXCESSIVE GLIOSIS AFTER VITRECTOMY FOR THE HIGHLY MYOPIC MACULAR HOLE: A Spectral Domain Optical Coherence Tomography Study

Overview
Journal Retina
Date 2023 Jan 25
PMID 36695791
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To investigate different modes of foveal regeneration after the closure of idiopathic macular hole (IMH) or highly myopic macular hole (HMMH) by vitrectomy with internal limiting membranes peeling or flap techniques.

Methods: This retrospective observational study followed 47 IMH and 50 HMMH eyes for at least 6 months. Twenty four IMH and 25 HMMH eyes underwent internal limiting membrane peeling, whereas 23 IMH and 25 HMMH eyes received inverted internal limiting membrane flap technique. Spectral domain optical coherence tomography was used to analyze macular hole closure, foveal microstructures, and excessive gliosis as a foveal "peak-like" protuberance.

Results: A single procedure closed all IMH (n = 47). For HMMH, the inverted group (n = 25, 100%) closed more macular hole than the peeling group (n = 14, 56.00%) (P < 0.001). Excessive gliosis only occurred in the inverted group, and there was a significant difference (P = 0.005) in incidence between IMH (three in 23 eyes, 13.04%) and HMMH (13 in 25 eyes, 52.00%). The axial length more than 29.985 mm enhanced the risk of excessive gliosis.

Conclusion: The inverted internal limiting membrane flap efficiently treated refractory MHs but was prone to cause excessive gliosis in highly myopic eyes. Excessive elongation of the globe (axial length > 29.985 mm) was linked to excessive gliosis growth.

Citing Articles

In vivo assessment of cone loss and macular perfusion in children with myopia.

Shen Y, Ye X, Zhou X, Yu J, Zhang C, He S Sci Rep. 2024; 14(1):26373.

PMID: 39487258 PMC: 11530448. DOI: 10.1038/s41598-024-78280-y.


Meta-regression of idiopathic full-thickness macular holes diameter and anatomical closure rate: Implications to intraoperative technique.

Zhang R, Fang Y, Shi X, Wu H, Yu C, Li Y Heliyon. 2024; 10(17):e36588.

PMID: 39263185 PMC: 11387363. DOI: 10.1016/j.heliyon.2024.e36588.


Shortfalls of free autologous internal limiting membrane transplantation for highly myopic refractory macular holes in a long term follow-up.

Carla M, Mateo C Graefes Arch Clin Exp Ophthalmol. 2024; 262(11):3531-3541.

PMID: 38832954 PMC: 11584440. DOI: 10.1007/s00417-024-06533-7.


Severe Gliosis Over a Closed Macular Hole Following Anterior Lens Capsular Flap Closure.

Temkar S, Rajasekar G, Jayaseelan J, Deb A, Ramachandar H Cureus. 2024; 16(2):e54190.

PMID: 38496174 PMC: 10941997. DOI: 10.7759/cureus.54190.


Biosensor-Based Multimodal Deep Human Locomotion Decoding via Internet of Healthcare Things.

Javeed M, Abdelhaq M, Algarni A, Jalal A Micromachines (Basel). 2023; 14(12).

PMID: 38138373 PMC: 10745656. DOI: 10.3390/mi14122204.