Feasibility of Electrodermal Activity and Photoplethysmography Data Acquisition at the Foot Using a Sock Form Factor

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2023 Jan 21
PMID 36679418
Authors
Affiliations
Soon will be listed here.
Abstract

Wearable devices have been shown to play an important role in disease prevention and health management, through the multimodal acquisition of peripheral biosignals. However, many of these wearables are exposed, limiting their long-term acceptability by some user groups. To overcome this, a wearable smart sock integrating a PPG sensor and an EDA sensor with textile electrodes was developed. Using the smart sock, EDA and PPG measurements at the foot/ankle were performed in test populations of 19 and 15 subjects, respectively. Both measurements were validated by simultaneously recording the same signals with a standard device at the hand. For the EDA measurements, Pearson correlations of up to 0.95 were obtained for the SCL component, and a mean consensus of 69% for peaks detected in the two locations was obtained. As for the PPG measurements, after fine-tuning the automatic detection of systolic peaks, the index finger and ankle, accuracies of 99.46% and 87.85% were obtained, respectively. Moreover, an HR estimation error of 17.40±14.80 Beats-Per-Minute (BPM) was obtained. Overall, the results support the feasibility of this wearable form factor for unobtrusive EDA and PPG monitoring.

Citing Articles

Measuring dynamic emotional experiences in response to media stimuli.

Winkler J, Appel M Front Psychol. 2025; 15:1436918.

PMID: 39742047 PMC: 11685027. DOI: 10.3389/fpsyg.2024.1436918.


Benchmarking of Sensor Configurations and Measurement Sites for Out-of-the-Lab Photoplethysmography.

Supelnic M, Ferreira A, Bota P, Bras-Rosario L, da Silva H Sensors (Basel). 2024; 24(1).

PMID: 38203076 PMC: 10781263. DOI: 10.3390/s24010214.

References
1.
Baker L . Physiology of sweat gland function: The roles of sweating and sweat composition in human health. Temperature (Austin). 2019; 6(3):211-259. PMC: 6773238. DOI: 10.1080/23328940.2019.1632145. View

2.
Payne A, Schell A, Dawson M . Lapses in skin conductance responding across anatomical sites: Comparison of fingers, feet, forehead, and wrist. Psychophysiology. 2016; 53(7):1084-92. DOI: 10.1111/psyp.12643. View

3.
Hong S, Park K . Unobtrusive Photoplethysmographic Monitoring Under the Foot Sole while in a Standing Posture. Sensors (Basel). 2018; 18(10). PMC: 6210668. DOI: 10.3390/s18103239. View

4.
Jarchi D, Casson A . Estimation of heart rate from foot worn photoplethysmography sensors during fast bike exercise. Annu Int Conf IEEE Eng Med Biol Soc. 2017; 2016:3155-2158. DOI: 10.1109/EMBC.2016.7591398. View

5.
Vieluf S, Amengual-Gual M, Zhang B, El Atrache R, Ufongene C, Jackson M . Twenty-four-hour patterns in electrodermal activity recordings of patients with and without epileptic seizures. Epilepsia. 2021; 62(4):960-972. DOI: 10.1111/epi.16843. View