» Articles » PMID: 36674047

Test-Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise

Overview
Publisher MDPI
Date 2023 Jan 21
PMID 36674047
Authors
Affiliations
Soon will be listed here.
Abstract

Background: the main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols.

Methods: twenty-eight healthy young adults volunteered to participate in this study. They attended the laboratory on four different days and performed four sessions: two of three sets of 12 repetitions at 75% 1RM and two of three sets of 30 repetitions at 50% 1RM. The range of movement (ROM), mean dynamic strength (MDS), peak dynamic strength (PDS), mean velocity (MV), peak velocity (PV), mean potency (MP), peak potency (PP), work (W), and impulse (I) were recorded. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) were obtained.

Results: reliability was very high for ROM (CV: 3.72%, ICC: 0.95), MDS (CV: 1.09%, ICC: 1.00), PDS (CV: 1.97%, ICC: 1.00), and W (CV: 4.69%, ICC: 1.00) conditions at 50% 1RM and for ROM (CV: 3.90%, ICC: 0.95), MDS (CV: 0.52, ICC: 1.00), PDS (CV: 1.49%, ICC: 0.98), and W (CV: 4.14%, ICC: 1.00) conditions at 75% 1RM and high for the rest of variables at 50 and 75% 1RM.

Conclusions: this study demonstrates that FEMD is a reliable instrument to measure ROM, MDS, PDS, MV, PV, PV, MP, MP, W, and I during both squat protocols (50 and 75% 1RM) in healthy young adults.

Citing Articles

Intra-session reliability of knee flexion-extension muscle strength monitored using a functional electromechanical dynamometer in female soccer players.

Andrades-Ramirez O, Ulloa-Diaz D, Castillo B, Saavedra-Ibaca V, Munoz-Bustos G, Chirosa-Rios L Front Physiol. 2025; 16:1542492.

PMID: 40070457 PMC: 11893584. DOI: 10.3389/fphys.2025.1542492.


The influence of physical activity levels on lactate production during squat training using a functional electromechanical dynamometer.

Del-Cuerpo I, Jerez-Mayorga D, Chirosa-Rios L, Caamano-Navarrete F, Delgado-Floody P PeerJ. 2025; 13:e18215.

PMID: 39872030 PMC: 11771300. DOI: 10.7717/peerj.18215.


Intra-session reliability of isometric muscle strength of the bilateral standing press in female handball players.

Cifuentes-Zapata C, Andrades-Ramirez O, Ulloa-Diaz D, Rodriguez-Perea A, Huerta Ojeda A, Chirosa-Rios L PeerJ. 2024; 12:e18196.

PMID: 39346033 PMC: 11439392. DOI: 10.7717/peerj.18196.


Test-Retest Reliability of an Isometric and Isometric/Vibratory Muscular Strength Protocol with Functional Electro-Mechanical Dynamometry.

Andrades-Ramirez O, Ulloa-Diaz D, Castillo B, Arroyo-Jofre P, Castillo-Paredes A, Chirosa-Rios L Sports (Basel). 2024; 12(7).

PMID: 39058066 PMC: 11280515. DOI: 10.3390/sports12070175.


Strength characteristics in faster change of direction basketball players: A comparison across cutting angles.

Barrera-Dominguez F, Del-Cuerpo I, Riego-Ruiz A, Martinez-Garcia D, Jerez-Mayorga D, Chirosa-Rios L Eur J Sport Sci. 2024; 24(9):1260-1269.

PMID: 38949958 PMC: 11369323. DOI: 10.1002/ejsc.12164.


References
1.
Bily W, Franz C, Trimmel L, Loefler S, Cvecka J, Zampieri S . Effects of Leg-Press Training With Moderate Vibration on Muscle Strength, Pain, and Function After Total Knee Arthroplasty: A Randomized Controlled Trial. Arch Phys Med Rehabil. 2016; 97(6):857-65. DOI: 10.1016/j.apmr.2015.12.015. View

2.
Caserotti P, Aagaard P, Larsen J, Puggaard L . Explosive heavy-resistance training in old and very old adults: changes in rapid muscle force, strength and power. Scand J Med Sci Sports. 2008; 18(6):773-82. DOI: 10.1111/j.1600-0838.2007.00732.x. View

3.
Morrow Jr J, Jackson A . How "significant" is your reliability?. Res Q Exerc Sport. 1993; 64(3):352-5. DOI: 10.1080/02701367.1993.10608821. View

4.
Cetin O, Akyildiz Z, Demirtas B, Sungur Y, Clemente F, Cazan F . Reliability and validity of the multi-point method and the 2-point method's variations of estimating the one-repetition maximum for deadlift and back squat exercises. PeerJ. 2022; 10:e13013. PMC: 8898007. DOI: 10.7717/peerj.13013. View

5.
Chamorro C, De la Fuente C, Rubio J, Campos C, Chirosa L . Absolute reliability and concurrent validity of a novel electromechanical pulley dynamometer for measuring shoulder rotation isometric strength in asymptomatic subjects. Study conducted at Pontificia Universidad Católica, Santiago, Chile. J Pak Med Assoc. 2019; 69(7):1000-1005. View