» Articles » PMID: 36645514

Effects of a Microgravity SkinSuit on Lumbar Geometry and Kinematics

Overview
Journal Eur Spine J
Specialty Orthopedics
Date 2023 Jan 16
PMID 36645514
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Astronauts returning from long ISS missions have demonstrated an increased incidence of lumbar disc herniation accompanied by biomechanical and morphological changes associated with spine elongation. This research describes a ground-based study of the effects of an axial compression countermeasure Mk VI SkinSuit designed to reload the spine and reduce these changes before return to terrestrial gravity.

Methods: Twenty healthy male volunteers aged 21-36 without back pain participated. Each lay overnight on a Hyper Buoyancy Flotation (HBF) bed for 12 h on two occasions 6 weeks apart. On the second occasion participants donned a Mk VI SkinSuit designed to axially load the spine at 0.2 Gz during the last 4 h of flotation. Immediately after each exposure, participants received recumbent MRI and flexion-extension quantitative fluoroscopy scans of their lumbar spines, measuring differences between spine geometry and intervertebral kinematics with and without the SkinSuit. This was followed by the same procedure whilst weight bearing. Paired comparisons were performed for all measurements.

Results: Following Mk VI SkinSuit use, participants evidenced more flexion RoM at L3-4 (p = 0.01) and L4-5 (p = 0.003), more translation at L3-4 (p = 0.02), lower dynamic disc height at L5-S1 (p = 0.002), lower lumbar spine length (p = 0.01) and greater lordosis (p = 0.0001) than without the Mk VI SkinSuit. Disc cross-sectional area and volume were not significantly affected.

Conclusion: The MkVI SkinSuit restores lumbar mobility and lordosis following 4 h of wearing during hyper buoyancy flotation in a healthy control population and may be an effective countermeasure for post space flight lumbar disc herniation.

Citing Articles

Elastic textile-based wearable modulation of musculoskeletal load: A comprehensive review of passive exosuits and resistance clothing.

Talukder A, Jo J Wearable Technol. 2025; 6:e11.

PMID: 40071238 PMC: 11894418. DOI: 10.1017/wtc.2025.2.


Lunar and mars gravity induce similar changes in spinal motor control as microgravity.

Swanenburg J, Easthope C, Meinke A, Langenfeld A, Green D, Schweinhardt P Front Physiol. 2023; 14:1196929.

PMID: 37565140 PMC: 10411353. DOI: 10.3389/fphys.2023.1196929.

References
1.
Johnston S, Campbell M, Scheuring R, Feiveson A . Risk of herniated nucleus pulposus among U.S. astronauts. Aviat Space Environ Med. 2010; 81(6):566-74. DOI: 10.3357/asem.2427.2010. View

2.
Belavy D, Adams M, Brisby H, Cagnie B, Danneels L, Fairbank J . Disc herniations in astronauts: What causes them, and what does it tell us about herniation on earth?. Eur Spine J. 2015; 25(1):144-154. DOI: 10.1007/s00586-015-3917-y. View

3.
Chang D, Healey R, Snyder A, Sayson J, Macias B, Coughlin D . Lumbar Spine Paraspinal Muscle and Intervertebral Disc Height Changes in Astronauts After Long-Duration Spaceflight on the International Space Station. Spine (Phila Pa 1976). 2016; 41(24):1917-1924. PMC: 5588025. DOI: 10.1097/BRS.0000000000001873. View

4.
Jin L, Feng G, Reames D, Shimer A, Shen F, Li X . The effects of simulated microgravity on intervertebral disc degeneration. Spine J. 2013; 13(3):235-42. PMC: 3612270. DOI: 10.1016/j.spinee.2012.01.022. View

5.
Kordi M, Belavy D, Armbrecht G, Sheikh A, Felsenberg D, Trudel G . Loss and re-adaptation of lumbar intervertebral disc water signal intensity after prolonged bedrest. J Musculoskelet Neuronal Interact. 2015; 15(3):294-300. PMC: 5601243. View