» Articles » PMID: 36616986

Portable Prussian Blue-Based Sensor for Bacterial Detection in Urine

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2023 Jan 8
PMID 36616986
Authors
Affiliations
Soon will be listed here.
Abstract

Bacterial infections can affect the skin, lungs, blood, and brain, and are among the leading causes of mortality globally. Early infection detection is critical in diagnosis and treatment but is a time- and work-consuming process taking several days, creating a hitherto unmet need to develop simple, rapid, and accurate methods for bacterial detection at the point of care. The most frequent type of bacterial infection is infection of the urinary tract. Here, we present a wireless-enabled, portable, potentiometric sensor for . was chosen as a model bacterium since it is the most common cause of urinary tract infections. The sensing principle is based on reduction of Prussian blue by the metabolic activity of the bacteria, detected by monitoring the potential of the sensor, transferring the sensor signal via Bluetooth, and recording the output on a laptop or a mobile phone. In sensing of bacteria in an artificial urine medium, was detected in ~4 h (237 ± 19 min; n = 4) and in less than 0.5 h (21 ± 7 min, n = 3) using initial concentrations of ~10 and 10 cells mL, respectively, which is under or on the limit for classification of a urinary tract infection. Detection of was also demonstrated in authentic urine samples with bacteria concentration as low as 10 cells mL, with a similar response recorded between urine samples collected from different volunteers as well as from morning and afternoon urine samples.

References
1.
Chen L, Yu L, Liu Y, Xu H, Ma L, Tian P . Space-time-regulated imaging analyzer for smart coagulation diagnosis. Cell Rep Med. 2022; 3(10):100765. PMC: 9589004. DOI: 10.1016/j.xcrm.2022.100765. View

2.
Chin C, Linder V, Sia S . Lab-on-a-chip devices for global health: past studies and future opportunities. Lab Chip. 2006; 7(1):41-57. DOI: 10.1039/b611455e. View

3.
Pilas J, Selmer T, Keusgen M, Schoning M . Screen-Printed Carbon Electrodes Modified with Graphene Oxide for the Design of a Reagent-Free NAD-Dependent Biosensor Array. Anal Chem. 2019; 91(23):15293-15299. DOI: 10.1021/acs.analchem.9b04481. View

4.
Qiao Y, Li C, Bao S, Lu Z, Hong Y . Direct electrochemistry and electrocatalytic mechanism of evolved Escherichia coli cells in microbial fuel cells. Chem Commun (Camb). 2008; (11):1290-2. DOI: 10.1039/b719955d. View

5.
Nicolle L . Urinary tract infections in long-term-care facilities. Infect Control Hosp Epidemiol. 2001; 22(3):167-75. DOI: 10.1086/501886. View