» Articles » PMID: 36582382

Accuracy of Steps Measured by Smartphones-based WeRun Compared with ActiGraph-GT3X Accelerometer in Free-living Conditions

Overview
Specialty Public Health
Date 2022 Dec 30
PMID 36582382
Authors
Affiliations
Soon will be listed here.
Abstract

Objectives: The purpose of this study was to evaluate the accuracy and reliability of steps tracked by smartphone-based WeChat app compared with Actigraph-GT3X accelerometer in free-living conditions.

Design: A cross-sectional study and repeated measures.

Methods: A total of 103 employees in the Pudong New Area of Shanghai, China, participated in this study. The participants wore an ActiGraph-GT3X accelerometer during the period of August to September 2019 (Time 1), December 2019 (Time 2) and September 2020 (Time 3). Each time, they wore the ActiGraph-GT3X accelerometer continuously for 7 days to assess their 7-day step counts. The smartphone-based WeRun step counts were collected in the corresponding period when subjects wore accelerometers. The subjects were invited to complete basic demographic characteristics questionnaires and to perform physical examination to obtain health-related results such as height, body weight, body fat percentage, waist circumference, hip circumference, and blood pressure.

Results: Based on 103 participants' 21 days of data, we found that the Spearman correlation coefficient between them was 0.733 ( < 0.01). The average number of WeRun steps measured by smartphones was 8,975 (4,059) per day, which was higher than those measured by accelerometers (8,462 ± 3,486 per day, < 0.01). Demographic characteristics and different conditions can affect the consistency of measurements. The consistency was higher in those who were male, older, master's degree and above educated, and traveled by walking. Steps measured by smartphone and accelerometer in working days and August showed stronger correlation than other working conditions and time. Mean absolute percent error (MAPE) for step counts ranged from 0.5 to 15.9%. The test-retest reliability coefficients of WeRun steps ranged from 0.392 to 0.646. A multiple regression analysis adjusted for age, gender, and MVPA/step counts measured during Time 1 showed that body composition (body weight, BMI, body fat percentage, waist circumference, and hip circumference) was correlated with moderate-to-vigorous intensity physical activity, but it was not correlated with WeRun step counts.

Conclusions: The smartphone-based WeChat app can be used to assess physical activity step counts and is a reliable tool for measuring steps in free-living conditions. However, WeRun step counts' utilization is potentially limited in predicting body composition.

References
1.
Aadland E, Ylvisaker E . Reliability of the Actigraph GT3X+ Accelerometer in Adults under Free-Living Conditions. PLoS One. 2015; 10(8):e0134606. PMC: 4537282. DOI: 10.1371/journal.pone.0134606. View

2.
Macfarlane D, Lee C, Ho E, Chan K, Chan D . Convergent validity of six methods to assess physical activity in daily life. J Appl Physiol (1985). 2006; 101(5):1328-34. DOI: 10.1152/japplphysiol.00336.2006. View

3.
Klinker C, Schipperijn J, Christian H, Kerr J, Ersboll A, Troelsen J . Using accelerometers and global positioning system devices to assess gender and age differences in children's school, transport, leisure and home based physical activity. Int J Behav Nutr Phys Act. 2014; 11:8. PMC: 3905652. DOI: 10.1186/1479-5868-11-8. View

4.
Donaire-Gonzalez D, de Nazelle A, Seto E, Mendez M, Nieuwenhuijsen M, Jerrett M . Comparison of physical activity measures using mobile phone-based CalFit and Actigraph. J Med Internet Res. 2013; 15(6):e111. PMC: 3713904. DOI: 10.2196/jmir.2470. View

5.
An K . Comparison between walking and moderate-to-vigorous physical activity: associations with metabolic syndrome components in Korean older adults. Epidemiol Health. 2020; 42:e2020066. PMC: 7871155. DOI: 10.4178/epih.e2020066. View