» Articles » PMID: 36575227

Comparison of Advanced Generation Cryoballoon Ablation and Ablation Index-guided Pulmonary Vein Isolation with Non-pulmonary Vein Trigger Induction Test and Additional Ablation in Paroxysmal Atrial Fibrillation

Abstract

Background: An ablation index (AI)-guided pulmonary vein isolation (PVI) or 2nd generation cryoballoon (CB)-PVI has been shown to reduce the atrial fibrillation (AF) burden by 99% despite the absence of ablation of non-pulmonary vein (PV) triggers in patients with paroxysmal AF. The purpose of this study was to investigate the effects of PVI alone strategy using 2nd generation CB compared with AI-guided PVI with an additional induction test and subsequent AF trigger ablation.

Methods And Results: We investigated 223 patients with symptomatic paroxysmal AF who underwent an initial PVI between August 2018 and August 2020. The study patients were divided into 2 groups: CB-PVI without an induction test (CB-PVI alone group, n = 82) and AI-guided PVI with an induction test and subsequent additional ablation of non-PV triggers (AI-PVI plus group, n = 141). In the AI-PVI plus group, a total of 62 non-PV triggers were induced in 38 patients, and non-PV triggers in 22 patients were completely ablated. The procedure time and left atrium dwell time were significantly shorter in the CB-PVI alone group than AI-PVI plus group. There were no significant differences in the incidence of procedural complications between the 2 groups (P = 0.650). The AF free survival rate in the CB-PVI alone group and AI-PVI plus group was 80% vs. 80% at 24 months (P = 0.969).

Conclusions: An PVI alone strategy using advanced generation CB did not differ in the clinical outcomes compared with an AI-guided PVI strategy with an induction test and subsequent ablation of non-PV triggers in the patients with paroxysmal AF.

References
1.
Fuster V, Ryden L, Cannom D, Crijns H, Curtis A, Ellenbogen K . ACC/AHA/ESC 2006 Guidelines for the Management of Patients with Atrial Fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the European Society of Cardiology Committee for.... Circulation. 2006; 114(7):e257-354. DOI: 10.1161/CIRCULATIONAHA.106.177292. View

2.
Hindricks G, Potpara T, Dagres N, Arbelo E, Bax J, Blomstrom-Lundqvist C . 2020 ESC Guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS): The Task Force for the diagnosis and management of atrial fibrillation of the.... Eur Heart J. 2020; 42(5):373-498. DOI: 10.1093/eurheartj/ehaa612. View

3.
Zhao Y, Di Biase L, Trivedi C, Mohanty S, Bai R, Mohanty P . Importance of non-pulmonary vein triggers ablation to achieve long-term freedom from paroxysmal atrial fibrillation in patients with low ejection fraction. Heart Rhythm. 2015; 13(1):141-9. DOI: 10.1016/j.hrthm.2015.08.029. View

4.
Kato N, Nitta J, Sato A, Inamura Y, Takamiya T, Inaba O . Characteristics of the nonpulmonary vein foci induced after second-generation cryoballoon ablation for paroxysmal atrial fibrillation. J Cardiovasc Electrophysiol. 2019; 31(1):174-184. DOI: 10.1111/jce.14314. View

5.
Chang H, Lo L, Lin Y, Chang S, Hu Y, Li C . Long-term outcome of catheter ablation in patients with atrial fibrillation originating from nonpulmonary vein ectopy. J Cardiovasc Electrophysiol. 2012; 24(3):250-8. DOI: 10.1111/jce.12036. View