Comparison of Advanced Generation Cryoballoon Ablation and Ablation Index-guided Pulmonary Vein Isolation with Non-pulmonary Vein Trigger Induction Test and Additional Ablation in Paroxysmal Atrial Fibrillation
Overview
Authors
Affiliations
Background: An ablation index (AI)-guided pulmonary vein isolation (PVI) or 2nd generation cryoballoon (CB)-PVI has been shown to reduce the atrial fibrillation (AF) burden by 99% despite the absence of ablation of non-pulmonary vein (PV) triggers in patients with paroxysmal AF. The purpose of this study was to investigate the effects of PVI alone strategy using 2nd generation CB compared with AI-guided PVI with an additional induction test and subsequent AF trigger ablation.
Methods And Results: We investigated 223 patients with symptomatic paroxysmal AF who underwent an initial PVI between August 2018 and August 2020. The study patients were divided into 2 groups: CB-PVI without an induction test (CB-PVI alone group, n = 82) and AI-guided PVI with an induction test and subsequent additional ablation of non-PV triggers (AI-PVI plus group, n = 141). In the AI-PVI plus group, a total of 62 non-PV triggers were induced in 38 patients, and non-PV triggers in 22 patients were completely ablated. The procedure time and left atrium dwell time were significantly shorter in the CB-PVI alone group than AI-PVI plus group. There were no significant differences in the incidence of procedural complications between the 2 groups (P = 0.650). The AF free survival rate in the CB-PVI alone group and AI-PVI plus group was 80% vs. 80% at 24 months (P = 0.969).
Conclusions: An PVI alone strategy using advanced generation CB did not differ in the clinical outcomes compared with an AI-guided PVI strategy with an induction test and subsequent ablation of non-PV triggers in the patients with paroxysmal AF.