» Articles » PMID: 36498111

CO Concentrations and Thermal Comfort Analysis at Onsite and Online Educational Environments

Overview
Publisher MDPI
Date 2022 Dec 11
PMID 36498111
Authors
Affiliations
Soon will be listed here.
Abstract

In building areas with high occupancy, such as classrooms, transmission routes of SARS-CoV-2 are increased when indoor air quality is deficient. Under this scenario, universities have adopted ventilation measures to mitigate contagious environments. However, the lack of adequate equipment or designs in old educational buildings is a barrier to reach minimum requirements. This study aims to quantify the indoor air quality and thermal comfort at universities and compare it to conditions in students' households. In this regard, several classrooms in buildings of the Polytechnic University of Catalonia were monitored for temperature, CO concentration and relative humidity. The people who used these classrooms were surveyed about their comfort perceptions. A sample of students was also monitored at their homes where they reported to studying during the exam period. By means of point-in-time surveys, students reported their daily comfort, for comparison with the monitored data. The results show that the recommendations for CO concentration, temperature, and relative humidity are not always met in any of the study spaces. These factors are more critical at universities due to the high occupancy. In addition, the surveys highlighted the perception that the environment is better at home than at university.

Citing Articles

Indoor Air Quality and COVID-19: A Scoping Review.

Braggion A, Dugerdil A, Wilson O, Hovagemyan F, Flahault A Public Health Rev. 2024; 44:1605803.

PMID: 38273885 PMC: 10810127. DOI: 10.3389/phrs.2023.1605803.

References
1.
Peng Z, Jimenez J . Exhaled CO as a COVID-19 Infection Risk Proxy for Different Indoor Environments and Activities. Environ Sci Technol Lett. 2023; 8(5):392-397. DOI: 10.1021/acs.estlett.1c00183. View

2.
Du C, Wang S, Yu M, Chiu T, Wang J, Chuang P . Effect of ventilation improvement during a tuberculosis outbreak in underventilated university buildings. Indoor Air. 2019; 30(3):422-432. PMC: 7217216. DOI: 10.1111/ina.12639. View

3.
Chen J . Novel statistics predict the COVID-19 pandemic could terminate in 2022. J Med Virol. 2022; 94(6):2845-2848. PMC: 9088340. DOI: 10.1002/jmv.27661. View

4.
Guo M, Xu P, Xiao T, He R, Dai M, Miller S . Review and comparison of HVAC operation guidelines in different countries during the COVID-19 pandemic. Build Environ. 2020; 187:107368. PMC: 7548082. DOI: 10.1016/j.buildenv.2020.107368. View

5.
Lowen A, Steel J, Mubareka S, Palese P . High temperature (30 degrees C) blocks aerosol but not contact transmission of influenza virus. J Virol. 2008; 82(11):5650-2. PMC: 2395183. DOI: 10.1128/JVI.00325-08. View