» Articles » PMID: 36457893

Res-SE-ConvNet: A Deep Neural Network for Hypoxemia Severity Prediction for Hospital In-Patients Using Photoplethysmograph Signal

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Determining the severity level of hypoxemia, the scarcity of saturated oxygen (SpO2) in the human body, is very important for the patients, a matter which has become even more significant during the outbreak of Covid-19 variants. Although the widespread usage of Pulse Oximeter has helped the doctors aware of the current level of SpO2 and thereby determine the hypoxemia severity of a particular patient, the high sensitivity of the device can lead to the desensitization of the care-givers, resulting in slower response to actual hypoxemia event. There has been research conducted for the detection of severity level using various parameters and bio-signals and feeding them in a machine learning algorithm. However, in this paper, we have proposed a new residual-squeeze-excitation-attention based convolutional network (Res-SE-ConvNet) using only Photoplethysmography (PPG) signal for the comfortability of the patient. Unlike the other methods, the proposed method has outperformed the standard state-of-art methods as the result shows 96.5% accuracy in determining 3 class severity problems with 0.79 Cohen Kappa score. This method has the potential to aid the patients in receiving the benefit of an automatic and faster clinical decision support system, thus handling the severity of hypoxemia.

Citing Articles

Overview of Wearable Healthcare Devices for Clinical Decision Support in the Prehospital Setting.

Gathright R, Mejia I, Gonzalez J, Hernandez Torres S, Berard D, Snider E Sensors (Basel). 2025; 24(24.

PMID: 39771939 PMC: 11679471. DOI: 10.3390/s24248204.


Multiple Field-of-View Based Attention Driven Network for Weakly Supervised Common Bile Duct Stone Detection.

Chang Y, Lin M, Hsieh M, Ou M, Huang C, Sheu B IEEE J Transl Eng Health Med. 2023; 11:394-404.

PMID: 37465459 PMC: 10351611. DOI: 10.1109/JTEHM.2023.3286423.


COVID-19 Detection Using Photoplethysmography and Neural Networks.

Lombardi S, Francia P, Deodati R, Calamai I, Luchini M, Spina R Sensors (Basel). 2023; 23(5).

PMID: 36904763 PMC: 10007577. DOI: 10.3390/s23052561.

References
1.
De Jong A, Rolle A, Molinari N, Paugam-Burtz C, Constantin J, Lefrant J . Cardiac Arrest and Mortality Related to Intubation Procedure in Critically Ill Adult Patients: A Multicenter Cohort Study. Crit Care Med. 2017; 46(4):532-539. DOI: 10.1097/CCM.0000000000002925. View

2.
Goldberger A, Amaral L, Glass L, Hausdorff J, Ivanov P, Mark R . PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation. 2000; 101(23):E215-20. DOI: 10.1161/01.cir.101.23.e215. View

3.
Hughes C, McGrane S, Pandharipande P . Sedation in the intensive care setting. Clin Pharmacol. 2012; 4:53-63. PMC: 3508653. DOI: 10.2147/CPAA.S26582. View

4.
Geng W, Jia D, Wang Y, Jin S, Ren Y, Liang D . A prediction model for hypoxemia during routine sedation for gastrointestinal endoscopy. Clinics (Sao Paulo). 2018; 73:e513. PMC: 6218956. DOI: 10.6061/clinics/2018/e513. View

5.
Talke P, Stapelfeldt C . Effect of peripheral vasoconstriction on pulse oximetry. J Clin Monit Comput. 2006; 20(5):305-9. DOI: 10.1007/s10877-006-9022-3. View