Routine Intraoperative Use of Esophageal Bougie in Minimally Invasive Hiatal Hernia Repair is Not Necessary

Overview
Journal JSLS
Specialty General Surgery
Date 2022 Dec 1
PMID 36452904
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Laparoscopic hiatal hernia repair can be performed with an antireflux procedure. Routine use of an esophageal bougie has been advocated to avoid an excessively tight fundoplication. The use of an esophageal bougie carries a risk of iatrogenic complications, such as perforation or laceration of the viscera. However, there is equivocal evidence for the routine use in the surgical literature.

Methods: We present a retrospective analysis of patients with Types 3 and 4 paraesophageal hiatal hernias who underwent laparoscopic hiatal hernia repair with fundoplication without the use of an esophageal bougie, between December 1, 2010 and February 28, 2020, by a single surgeon at a community-based, academic hospital. Patients with a diagnosis of achalasia and gastroesophageal dysmotility were excluded. Perioperative outcome measures included: recurrence; prolonged postoperative proton pump inhibitor use; dysphagia; re-operation, and mortality.

Results: A total of 174 patients (34 males, 140 females) underwent laparoscopic hiatal hernia repair with fundoplication. The average age was 63-years old. Four patients (2.3%) developed dysphagia with narrowing of the gastroesophageal junction, with one patient (0.6%) requiring postoperative esophageal dilation with bougie and eventual re-operation. Postoperative proton pump inhibitor use was 31.0% after 1 month. Overall hernia recurrence rate was 14.9% and the rate of re-operation was 6.3%. Overall mortality was 0.6%.

Conclusion: We conclude that laparoscopic hiatal hernia repair with fundoplication without an esophageal bougie is safe, effective, and efficient. Furthermore, bougie related risks are obviated with a comparable reported incidence of postoperative dysphagia and hiatal hernia recurrence.

Citing Articles

Impact of Toupet fundoplication with bougie on post-operative dysphagia and quality of life.

Anderson D, Kuchta K, Joseph S, Rwigema J, Crafts T, Ishii S Surg Endosc. 2024; 38(9):5350-5355.

PMID: 39028347 DOI: 10.1007/s00464-024-11038-9.


The role of anterior gastropexy in elderly Japanese hiatal hernia patients.

Yokouchi T, Nakajima K, Takahashi T, Yamashita K, Saito T, Tanaka K Surg Today. 2024; 54(9):1051-1057.

PMID: 38514475 DOI: 10.1007/s00595-024-02809-x.

References
1.
Patterson E, Herron D, Hansen P, Ramzi N, Standage B, Swanstrom L . Effect of an esophageal bougie on the incidence of dysphagia following nissen fundoplication: a prospective, blinded, randomized clinical trial. Arch Surg. 2000; 135(9):1055-61; discussion 1061-2. DOI: 10.1001/archsurg.135.9.1055. View

2.
Ng A, Yong D, Hazebroek E, Berry H, Radajewski R, Leibman S . Omission of the calibration bougie in laparoscopic repair of paraesophageal hernia. Surg Endosc. 2009; 23(11):2505-8. DOI: 10.1007/s00464-009-0426-2. View

3.
Chang C, Thackeray L . Laparoscopic Hiatal Hernia Repair in 221 Patients: Outcomes and Experience. JSLS. 2016; 20(1). PMC: 4754198. DOI: 10.4293/JSLS.2015.00104. View

4.
Huttl T, Hohle M, Wichmann M, Jauch K, Meyer G . Techniques and results of laparoscopic antireflux surgery in Germany. Surg Endosc. 2005; 19(12):1579-87. DOI: 10.1007/s00464-005-0163-0. View

5.
Kohn G, Price R, DeMeester S, Zehetner J, Muensterer O, Awad Z . Guidelines for the management of hiatal hernia. Surg Endosc. 2013; 27(12):4409-28. DOI: 10.1007/s00464-013-3173-3. View