Investigation on the Effectiveness of Ventilation Dilution on Mitigating COVID-19 Patients' Secondary Airway Damage Due to Exposure to Disinfectants

Overview
Journal Build Environ
Date 2022 Nov 21
PMID 36407877
Authors
Affiliations
Soon will be listed here.
Abstract

Chlorine-containing disinfectants are widely used in hospitals to prevent hospital-acquired severe acute respiratory syndrome coronavirus 2 infection. Meanwhile, ventilation is a simple but effective means to maintain clean air. It is essential to explore the exposure level and health effects of coronavirus disease 2019 patients' inhalation exposure to by-products of chloride-containing disinfectants under frequent surface disinfection and understand the role of ventilation in mitigating subsequent airway damage. We determined ventilation dilution performance and indoor air quality of two intensive care unit wards of the largest temporary hospital constructed in China, Leishenshan Hospital. The chloride inhalation exposure levels, and health risks indicated by interleukin-6 and D-dimer test results of 32 patients were analysed. The mean ± standard deviation values of the outdoor air change rate in the two intensive care unit wards were 8.8 ± 1.5 h (Intensive care unit 1) and 4.1 ± 1.4 h (Intensive care unit 2). The median carbon dioxide and fine particulate matter concentrations were 480 ppm and 19 μg/m for intensive care unit 1, and 567 ppm and 21 μg/m for intensive care unit 2, all of which were around the average levels of those in permanent hospitals (579 ppm and 21 μg/m). Of these patients, the median (lower quartile, upper quartile) chloride exposure time and calculated dose were 26.66 (2.89, 57.21) h and 0.357 (0.008, 1.317) mg, respectively. A statistically significant positive correlation was observed between interleukin-6 and D-dimer concentrations. To conclude, ventilation helped maintain ward air cleanliness and health risks were not observed.

References
1.
Zheng G, Webster T, Salamova A . Quaternary Ammonium Compounds: Bioaccumulation Potentials in Humans and Levels in Blood before and during the Covid-19 Pandemic. Environ Sci Technol. 2021; 55(21):14689-14698. PMC: 8547165. DOI: 10.1021/acs.est.1c01654. View

2.
Hora P, Pati S, McNamara P, Arnold W . Increased Use of Quaternary Ammonium Compounds during the SARS-CoV-2 Pandemic and Beyond: Consideration of Environmental Implications. Environ Sci Technol Lett. 2023; 7(9):622-631. DOI: 10.1021/acs.estlett.0c00437. View

3.
Shajahan A, Culp C, Williamson B . Effects of indoor environmental parameters related to building heating, ventilation, and air conditioning systems on patients' medical outcomes: A review of scientific research on hospital buildings. Indoor Air. 2018; 29(2):161-176. PMC: 7165615. DOI: 10.1111/ina.12531. View

4.
Song W, Wei S, Liu G, Yu Z, Estell K, Yadav A . Postexposure administration of a {beta}2-agonist decreases chlorine-induced airway hyperreactivity in mice. Am J Respir Cell Mol Biol. 2010; 45(1):88-94. PMC: 3145072. DOI: 10.1165/rcmb.2010-0226OC. View

5.
Faridi S, Niazi S, Sadeghi K, Naddafi K, Yavarian J, Shamsipour M . A field indoor air measurement of SARS-CoV-2 in the patient rooms of the largest hospital in Iran. Sci Total Environ. 2020; 725:138401. PMC: 7194859. DOI: 10.1016/j.scitotenv.2020.138401. View