Left Ventricle Chest Compression Improves ETCO, Blood Pressure, and Cerebral Blood Velocity in a Swine Model of Cardiac Arrest and Cardiopulmonary Resuscitation
Overview
Authors
Affiliations
Introduction: During cardiopulmonary resuscitation (CPR), high quality chest compressions are critical to organ perfusion, especially the brain. Yet, the optimal location for chest compressions is unclear. It was hypothesized that compared with the standard chest compression (SCC) location, left ventricle chest compressions (LVCCs) would result in greater ETCO, blood pressure (BP), and cerebral blood velocity (CBV) during CPR in swine.
Methods: Female Landrace swine (N = 32; 35 ± 2 kg) underwent two mins of untreated asphyxiated cardiac arrest (CA). Thereafter, swine were treated with three 2-min cycles of either SCC or LVCC mechanical basic life support CPR (LUCAS 3). ETCO (in-line sampling), BP (arterial catheter line), and CBV (transcranial Doppler) were measured during the pre-CA, untreated-CA, and CPR-treated phases.
Results: ETCO, BP, and CBV were similar between groups at pre- and during untreated-CA (P ≥ 0.188). During CPR, ETCO (36 ± 6 versus 24 ± 10 mmHg, P < 0.001), mean arterial BP (MAP; 49 ± 9 versus 37 ± 9 mmHg, P = 0.002), and CBV (11 ± 5 versus 5 ± 2 cm/s, P < 0.001) were significantly greater in the LVCC versus SCC group. Moreover, a greater proportion of animals obtained targets for ETCO (ETCO ≥ 20 mmHg; 52 % (17/33) versus 100 % (32/32), P < 0.001) and diastolic BP (DBP ≥ 25 mmHg; 82 % (33/40) versus 97 % (48/49), P = 0.020) in the LVCC versus SCC group.
Conclusion: Indicators of cardiac output, BP, and cerebral perfusion during CPR were greatest in the LVCC group, suggesting the quality of chest compressions during BLS CPR may be improved by performing compressions over the left ventricle compared to the centre of the chest.
Gould J, Marshall R, French D, Dyer-Heynen M, Olszynski P Resusc Plus. 2025; 21:100865.
PMID: 39897062 PMC: 11786900. DOI: 10.1016/j.resplu.2025.100865.
Physiology-Guided Resuscitation: Monitoring and Augmenting Perfusion during Cardiopulmonary Arrest.
Bernard S, Pashun R, Varma B, Yuriditsky E J Clin Med. 2024; 13(12).
PMID: 38930056 PMC: 11205151. DOI: 10.3390/jcm13123527.
Kopra J, Litonius E, Pekkarinen P, Laitinen M, Heinonen J, Fontanelli L Intensive Care Med Exp. 2024; 12(1):36.
PMID: 38607459 PMC: 11014827. DOI: 10.1186/s40635-024-00620-z.
Real-time feedback on chest compression efficacy by hands-free carotid Doppler in a porcine model.
Faldaas B, Nielsen E, Storm B, Lappegard K, Nilsen B, Kiss G Resusc Plus. 2024; 18:100583.
PMID: 38404755 PMC: 10885784. DOI: 10.1016/j.resplu.2024.100583.
Saksobhavivat N, Phattharapornjaroen P, Suksukon P, Atiksawedparit P, Chalermdamrichai P, Saelee R Sci Rep. 2023; 13(1):22763.
PMID: 38123619 PMC: 10733391. DOI: 10.1038/s41598-023-49486-3.