Free-breathing Myocardial T Mapping Using Inversion-recovery Radial FLASH and Motion-resolved Model-based Reconstruction

Overview
Journal Magn Reson Med
Publisher Wiley
Specialty Radiology
Date 2022 Nov 21
PMID 36404631
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To develop a free-breathing myocardial mapping technique using inversion-recovery (IR) radial fast low-angle shot (FLASH) and calibrationless motion-resolved model-based reconstruction.

Methods: Free-running (free-breathing, retrospective cardiac gating) IR radial FLASH is used for data acquisition at 3T. First, to reduce the waiting time between inversions, an analytical formula is derived that takes the incomplete recovery into account for an accurate calculation. Second, the respiratory motion signal is estimated from the k-space center of the contrast varying acquisition using an adapted singular spectrum analysis (SSA-FARY) technique. Third, a motion-resolved model-based reconstruction is used to estimate both parameter and coil sensitivity maps directly from the sorted k-space data. Thus, spatiotemporal total variation, in addition to the spatial sparsity constraints, can be directly applied to the parameter maps. Validations are performed on an experimental phantom, 11 human subjects, and a young landrace pig with myocardial infarction.

Results: In comparison to an IR spin-echo reference, phantom results confirm good accuracy, when reducing the waiting time from 5 s to 1 s using the new correction. The motion-resolved model-based reconstruction further improves precision compared to the spatial regularization-only reconstruction. Aside from showing that a reliable respiratory motion signal can be estimated using modified SSA-FARY, in vivo studies demonstrate that dynamic myocardial maps can be obtained within 2 min with good precision and repeatability.

Conclusion: Motion-resolved myocardial mapping during free-breathing with good accuracy, precision and repeatability can be achieved by combining inversion-recovery radial FLASH, self-gating and a calibrationless motion-resolved model-based reconstruction.

Citing Articles

Accelerated Cartesian cardiac T2 mapping based on a calibrationless locally low-rank tensor constraint.

Gao J, Gong Y, Tang X, Chen H, Chen Z, Shen Y Quant Imaging Med Surg. 2024; 14(10):7654-7670.

PMID: 39429619 PMC: 11485370. DOI: 10.21037/qims-24-740.


Free-breathing 3D cardiac extracellular volume (ECV) mapping using a linear tangent space alignment (LTSA) model.

Lee W, Han P, Marin T, Mounime I, Vafay Eslahi S, Djebra Y Magn Reson Med. 2024; 93(2):536-549.

PMID: 39402014 PMC: 11606777. DOI: 10.1002/mrm.30284.


Motion-compensated T mapping in cardiovascular magnetic resonance imaging: a technical review.

Sheagren C, Cao T, Patel J, Chen Z, Lee H, Wang N Front Cardiovasc Med. 2023; 10:1160183.

PMID: 37790594 PMC: 10542904. DOI: 10.3389/fcvm.2023.1160183.


Pilot tone-based prospective correction of respiratory motion for free-breathing myocardial T1 mapping.

Ludwig J, Kerkering K, Speier P, Schaeffter T, Kolbitsch C MAGMA. 2022; 36(1):135-150.

PMID: 35921020 PMC: 9992053. DOI: 10.1007/s10334-022-01032-4.

References
1.
Chow K, Flewitt J, Green J, Pagano J, Friedrich M, Thompson R . Saturation recovery single-shot acquisition (SASHA) for myocardial T(1) mapping. Magn Reson Med. 2013; 71(6):2082-95. DOI: 10.1002/mrm.24878. View

2.
Liu Y, Hamilton J, Eck B, Griswold M, Seiberlich N . Myocardial T and T quantification and water-fat separation using cardiac MR fingerprinting with rosette trajectories at 3T and 1.5T. Magn Reson Med. 2020; 85(1):103-119. PMC: 10212526. DOI: 10.1002/mrm.28404. View

3.
Block K, Uecker M, Frahm J . Model-based iterative reconstruction for radial fast spin-echo MRI. IEEE Trans Med Imaging. 2009; 28(11):1759-69. DOI: 10.1109/TMI.2009.2023119. View

4.
Marty B, Coppa B, Carlier P . Fast, precise, and accurate myocardial T mapping using a radial MOLLI sequence with FLASH readout. Magn Reson Med. 2017; 79(3):1387-1398. DOI: 10.1002/mrm.26795. View

5.
Gensler D, Morchel P, Fidler F, Ritter O, Quick H, Ladd M . Myocardial T1: quantification by using an ECG-triggered radial single-shot inversion-recovery MR imaging sequence. Radiology. 2014; 274(3):879-87. DOI: 10.1148/radiol.14131295. View