» Articles » PMID: 36362865

Pre-Lens Tear Meniscus Height, Lipid Layer Pattern and Non-Invasive Break-Up Time Short-Term Changes with a Water Gradient Silicone Hydrogel Contact Lens

Overview
Journal Life (Basel)
Specialty Biology
Date 2022 Nov 11
PMID 36362865
Authors
Affiliations
Soon will be listed here.
Abstract

To evaluate pre-lens tear film volume, stability and lipid interferometry patterns with a silicone hydrogel water content contact lens, a novel, noninvasive, ocular-surface-analyzer technology was used. A prospective, longitudinal, single-center, self-control study was performed in daily or monthly replacement silicone hydrogel contact lens wearers. A tear film analysis was achieved with the Integrated Clinical Platform (ICP) Ocular Surface Analyzer (OSA) from SBM System. The subjects were reassessed, with the contact lens, after 30 min of wearing to quantify the volume, stability and lipid pattern of the short-term pre-lens tear film. Lipid layer thickness decreased from 2.05 ± 1.53 to 1.90 ± 1.73 Guillon patterns (p = 0.23). First pre-lens NIBUT decreased from 5.03 ± 1.04 to 4.63 ± 0.89 s (p = 0.01). Mean pre-lens NIBUT significantly increased from 15.19 ± 9.54 to 21.27 ± 11.97 s (p < 0.01). Lid opening time significantly increased from 26.36 ± 19.72 to 38.58 ± 21.78 s (p < 0.01). The silicone hydrogel contact lens with water gradient technology significantly increased the mean pre-lens NIBUT and lid opening time. Lehfilcon A suggested an improvement in contact lens wearers with tear film instability or decreased subjective symptoms of dry eye disease.

Citing Articles

Patient Satisfaction and Tear Film Break-Up Time After First-Time Wearing of Silicone Hydrogel Contact Lenses.

Misu N, Mimura T, Noma H, Shinbo K Cureus. 2024; 16(1):e52516.

PMID: 38371096 PMC: 10874256. DOI: 10.7759/cureus.52516.


Biomimetic-Engineered Silicone Hydrogel Contact Lens Materials.

Ishihara K, Shi X, Fukazawa K, Yamaoka T, Yao G, Wu J ACS Appl Bio Mater. 2023; 6(9):3600-3616.

PMID: 37616500 PMC: 10521029. DOI: 10.1021/acsabm.3c00296.


Tear Film Dynamics between Low and High Contact Lens Dry Eye Disease Questionnaire (CLDEQ-8) Score with a Lehfilcon A Silicone Hydrogel Water Gradient Contact Lens: A Non-Invasive Methodology Approach.

Capote-Puente R, Bautista-Llamas M, Sanchez-Gonzalez J Diagnostics (Basel). 2023; 13(5).

PMID: 36900083 PMC: 10001148. DOI: 10.3390/diagnostics13050939.

References
1.
Garcia-Montero M, Rico-Del-Viejo L, Llorens-Quintana C, Lorente-Velazquez A, Hernandez-Verdejo J, Madrid-Costa D . Randomized crossover trial of silicone hydrogel contact lenses. Cont Lens Anterior Eye. 2018; 42(5):475-481. DOI: 10.1016/j.clae.2018.12.006. View

2.
Pult H, Nichols J . A review of meibography. Optom Vis Sci. 2012; 89(5):E760-9. DOI: 10.1097/OPX.0b013e3182512ac1. View

3.
Lee S, Kim S, Park M . Oxygen permeability of soft contact lenses in different pH, osmolality and buffering solution. Int J Ophthalmol. 2015; 8(5):1037-42. PMC: 4631011. DOI: 10.3980/j.issn.2222-3959.2015.05.33. View

4.
Chalmers R, Keay L, Hickson-Curran S, Gleason W . Cutoff score and responsiveness of the 8-item Contact Lens Dry Eye Questionnaire (CLDEQ-8) in a Large daily disposable contact lens registry. Cont Lens Anterior Eye. 2016; 39(5):342-52. DOI: 10.1016/j.clae.2016.04.005. View

5.
Guillon M, Patel T, Patel K, Gupta R, Maissa C . Quantification of contact lens wettability after prolonged visual device use under low humidity conditions. Cont Lens Anterior Eye. 2019; 42(4):386-391. DOI: 10.1016/j.clae.2019.03.004. View