Expansion of the Application Domain of a Macromolecular Ocular Irritation Test (OptiSafe™)

Overview
Specialty Toxicology
Date 2022 Nov 9
PMID 36351539
Authors
Affiliations
Soon will be listed here.
Abstract

The OptiSafe (OS) test is shelf-stable, macromolecular eye irritation test that does not include any animal ingredient or component ("vegan"). The purpose of this study was to evaluate the test's accuracy for an expanded application domain for both the original and recently updated OS method. This study involved the testing of additional ocular corrosives and previously excluded foaming agents ("surfactants") using both the original and updated OS methods and then combining these data with prior validation data for a total of 147 chemicals. Predictivity was evaluated by a statistical comparison of the OptiSafe predictions with historical in vivo "Draize" rabbit eye data for the same chemicals (from public databases). We report that for the detection of chemicals not requiring classification for eye irritation [Globally Harmonized System of Classification and Labeling of Chemicals (GHS) No Category], the accuracy, specificity, and sensitivity were 92.8%, 79.6%, and 100.0%, respectively, for the updated method; for the detection of chemicals inducing extreme eye damage/corrosion (GHS Category 1), the accuracy, specificity, and sensitivity were 79.4%, 71.8%, and 91.7%, respectively, for the updated method. Results indicate that both the original and updated methods have a high accuracy for the expanded application domain that included ocular corrosives and surfactants.

Citing Articles

Washing with buffered vitamin C after corrosive chemical (sodium hypochlorite) exposure reduces ocular depth of injury.

Lebrun S, Nguyen L, Romero J, Chan R Toxicol In Vitro. 2025; 104:106006.

PMID: 39746384 PMC: 11884246. DOI: 10.1016/j.tiv.2024.106006.


Evaluation of a New In Chemico Skin Corrosion Test.

Lebrun S, Nguyen L, Ho K Toxicol In Vitro. 2024; 101():105944.

PMID: 39341469 PMC: 11737548. DOI: 10.1016/j.tiv.2024.105944.

References
1.
Adriaens E, Guest R, Willoughby Sr J, Fochtman P, Kandarova H, Verstraelen S . CON4EI: Slug Mucosal Irritation (SMI) test method for hazard identification and labelling of serious eye damaging and eye irritating chemicals. Toxicol In Vitro. 2017; 49:77-89. DOI: 10.1016/j.tiv.2017.08.020. View

2.
Lebrun S, Chavez S, Nguyen L, Chan R . Further optimisation of a macromolecular ocular irritation test (OptiSafe). Cutan Ocul Toxicol. 2023; 42(1):38-48. PMC: 10381028. DOI: 10.1080/15569527.2023.2170067. View

3.
Lebrun S, Nguyen L, Chavez S, Chan R, Le D, Nguyen M . Same-chemical comparison of nonanimal eye irritation test methods: Bovine corneal opacity and permeability, EpiOcular™, isolated chicken eye, ocular Irritection®, OptiSafe™, and short time exposure. Toxicol In Vitro. 2020; 72:105070. PMC: 8544240. DOI: 10.1016/j.tiv.2020.105070. View

4.
Alepee N, Grandidier M, Teluob S, Amaral F, Caviola E, De Servi B . Validation of the SkinEthic HCE Time-to-Toxicity test method for eye hazard classification of chemicals according to UN GHS. Toxicol In Vitro. 2022; 80:105319. DOI: 10.1016/j.tiv.2022.105319. View

5.
Van Rompay A, Alepee N, Nardelli L, Hollanders K, Leblanc V, Drzewiecka A . CON4EI: SkinEthic™ Human Corneal Epithelium Eye Irritation Test (SkinEthic™ HCE EIT) for hazard identification and labelling of eye irritating chemicals. Toxicol In Vitro. 2017; 49:11-20. DOI: 10.1016/j.tiv.2017.06.012. View