» Articles » PMID: 36348435

Ventricular Arrhythmia Burden in Patients with Implantable Cardioverter Defibrillator and Remote Patient Monitoring During Different Time Intervals of the COVID-19 Pandemic

Overview
Journal Eur J Med Res
Publisher Biomed Central
Specialty General Medicine
Date 2022 Nov 9
PMID 36348435
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: The current study investigated whether the changes in patient care in times of the COVID-19 pandemic, especially the reduction of in-person visits, would result in a deterioration of the arrhythmic and clinical condition of patients with an implantable cardioverter defibrillator (ICD) and remote patient monitoring.

Methods: Data were obtained from a local ICD registry. 140 patients who received ICD implantation at our department and had remote patient monitoring were included. The number of patients with ventricular arrhythmias, appropriate ICD therapy, the number of visits to our outpatient clinic and hospitalization due to acute coronary syndrome, stroke or heart failure were compared during three time intervals of the COVID-19 pandemic (first (LD1) and second (LD2) national lockdown in Germany and the time after the first lockdown (postLD1)) and a time interval 1 year before the pandemic began (preCOV). Each time interval was 49 days long.

Results: Patients had significantly fewer visits to our outpatient clinic during LD1 (n = 13), postLD1 (n = 22) and LD2 (n = 23) compared to the time interval before the pandemic (n = 43, each p ≤ 0.05). The number of patients with sustained ventricular arrhythmias, appropriate ICD therapy and clinical events showed no significant difference during the time intervals of the COVID-19 pandemic and the time interval 1 year prior.

Conclusions: The lockdown measures necessary to reduce the risk of infection during the COVID-19 pandemic, led to a reduction of in-person patient visits, but did not result in a deterioration of the arrhythmic and clinical condition of ICD patients with remote patient monitoring.

References
1.
Sassone B, Virzi S, Bertini M, Pasanisi G, Manzoli L, Myers J . Impact of the COVID-19 lockdown on the arrhythmic burden of patients with implantable cardioverter-defibrillators. Pacing Clin Electrophysiol. 2021; 44(6):1033-1038. PMC: 8207039. DOI: 10.1111/pace.14280. View

2.
Spencker S, Coban N, Koch L, Schirdewan A, Muller D . Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Europace. 2008; 11(4):483-8. DOI: 10.1093/europace/eun350. View

3.
Gasperetti A, Biffi M, Duru F, Schiavone M, Ziacchi M, Mitacchione G . Arrhythmic safety of hydroxychloroquine in COVID-19 patients from different clinical settings. Europace. 2020; 22(12):1855-1863. PMC: 7543547. DOI: 10.1093/europace/euaa216. View

4.
De Larochelliere H, Champagne J, Sarrazin J, Steinberg C, Philippon F, Roy K . Findings of remote monitoring of implantable cardioverter defibrillators during the COVID-19 pandemic. Pacing Clin Electrophysiol. 2020; 43(11):1366-1372. PMC: 7675613. DOI: 10.1111/pace.14086. View

5.
Chatterji P, Li Y . Effects of the COVID-19 Pandemic on Outpatient Providers in the United States. Med Care. 2020; 59(1):58-61. DOI: 10.1097/MLR.0000000000001448. View