» Articles » PMID: 36340910

Evaluation of an Infrared Thermography Camera for Measuring Body Temperature in Dairy Calves

Overview
Journal JDS Commun
Date 2022 Nov 7
PMID 36340910
Authors
Affiliations
Soon will be listed here.
Abstract

The objective of this diagnostic accuracy study was to validate an infrared thermography (IRT) camera and its software (FLIR One, FLIR, Global) for accuracy and precision for ocular temperature readings to serve as a proxy for rectal temperature in commercially housed calves. A total of 318 male Holstein calves were enrolled into this study from the day of arrival to a calf rearing facility until 14 d later. Researchers took an ocular temperature reading using an IRT camera, and a rectal temperature on each calf each day in the morning. The reference standard method for body temperature in the calves was rectal temperature. We assessed the data for agreement between the IRT and the reference standard using Pearson correlations by calf (accuracy), coefficients of determination (precision), and Bland-Altman plots for bias. In addition, a logistic regression model was built using the reference method as the outcome, with IRT as an explanatory variable to assess the diagnostic accuracy of IRT as an indicator of fever (rectal temperature ≥39.5°C). There was a negligible correlation between the IRT readings and rectal temperature (r = 0.22) and the coefficient of determination for IRT to predict rectal temperature was negligible (R = 0.05), suggesting poor precision. The average mean difference between the IRT data and rectal temperature was 0.55°C, and the differences between IRT and rectal formed a linear line around the mean difference, suggesting the Bland-Altman analyses showed proportional error and bias. The optimal probability cut-off for IRT readings for fever was at 39.5°C, and had a receiver operating characteristic area under the curve of 0.67, a sensitivity of 61%, a specificity of 71%, and 78% (3,134/4,427) of the samples were correctly labeled as either having a fever or not using IRT readings. In summary, the IRT camera and software were not validated for serving as a proxy for rectal temperature in commercially housed calves due to poor precision, and proportional error partially explained by ambient environmental conditions. We suggest that this infrared thermography system should not replace rectal temperature readings for use in commercially housed calves.

Citing Articles

Validation and interdevice reliability of a behavior monitoring collar to measure rumination, feeding activity, and idle time of lactating dairy cows.

Lovatti J, Dijkinga K, Aires J, Garrido L, Costa J, Daros R JDS Commun. 2024; 5(6):602-607.

PMID: 39650024 PMC: 11624420. DOI: 10.3168/jdsc.2023-0467.


Evaluation of a Temperature/Humidity Data Logger for the Usage in Cattle Barns.

Flessner M, Konig F, Guse C, Iwersen M, Klein-Jobstl D Sensors (Basel). 2024; 24(22).

PMID: 39598895 PMC: 11598373. DOI: 10.3390/s24227117.


Association between a pyroelectric infrared sensor monitoring system and a 3-dimensional accelerometer to assess movement in preweaning dairy calves.

Sonntag N, Borchardt S, Heuwieser W, Sutter F JDS Commun. 2024; 5(1):72-76.

PMID: 38223382 PMC: 10785259. DOI: 10.3168/jdsc.2023-0393.


Literature Review on Technological Applications to Monitor and Evaluate Calves' Health and Welfare.

Silva F, Conceicao C, Pereira A, Cerqueira J, Silva S Animals (Basel). 2023; 13(7).

PMID: 37048404 PMC: 10093142. DOI: 10.3390/ani13071148.

References
1.
Lowe G, McCane B, Sutherland M, Waas J, Schaefer A, Cox N . Automated Collection and Analysis of Infrared Thermograms for Measuring Eye and Cheek Temperatures in Calves. Animals (Basel). 2020; 10(2). PMC: 7070973. DOI: 10.3390/ani10020292. View

2.
Schaefer A, Cook N, Bench C, Chabot J, Colyn J, Liu T . The non-invasive and automated detection of bovine respiratory disease onset in receiver calves using infrared thermography. Res Vet Sci. 2011; 93(2):928-35. PMC: 7111736. DOI: 10.1016/j.rvsc.2011.09.021. View

3.
Hoffmann G, Schmidt M, Ammon C . First investigations to refine video-based IR thermography as a non-invasive tool to monitor the body temperature of calves. Animal. 2015; 10(9):1542-6. DOI: 10.1017/S1751731115001354. View

4.
Hoffmann G, Schmidt M, Ammon C, Rose-Meierhofer S, Burfeind O, Heuwieser W . Monitoring the body temperature of cows and calves using video recordings from an infrared thermography camera. Vet Res Commun. 2012; 37(2):91-9. DOI: 10.1007/s11259-012-9549-3. View

5.
Lowe G, Sutherland M, Waas J, Schaefer A, Cox N, Stewart M . Infrared Thermography-A Non-Invasive Method of Measuring Respiration Rate in Calves. Animals (Basel). 2019; 9(8). PMC: 6720651. DOI: 10.3390/ani9080535. View