» Articles » PMID: 36325083

Biomechanical Analysis of a New Eight-Strand Suture for Flexor Tendon Repair

Overview
Publisher Thieme
Specialty General Surgery
Date 2022 Nov 3
PMID 36325083
Authors
Affiliations
Soon will be listed here.
Abstract

 The placement of multistrand sutures during flexor tendon repair requires complicated surgical skills; such suturing is difficult. We developed a new, simpler eight-strand suture, which we term the Yoshizu cross-lock. This reduces the numbers of suture passages through the tendons, as well as the numbers of knots.  Fourteen porcine flexor tendons were transected and repaired using the Yoshizu cross-lock system; no peripheral sutures were placed. Our system is a modification of the published, exposed cross-lock repair method that employs a 4-0 monofilament nylon two-strand line and two needles. The repaired tendons were subjected to linear, noncyclic load-to-failure tensile testing. The initial gap, the 2-mm gap force, and the ultimate strength were measured.  The initial gap force was 12.6 ± 5.6 Newtons (N), the 2-mm gap force was 33.9 ± 10.9 N, and the ultimate strength was 70.1 ± 17.0 N. All tendons subjected to Yoshizu cross-lock repair failed due to suture rupture rather than pullout.  Our biomechanical study revealed that Yoshizu cross-lock repair had sufficient tensile strength but was associated with wide variation in the 2-mm gap load (standard deviation = 10.9 N). This study is clinically relevant, showing that the Yoshizu cross-lock repair combined with peripheral suturing may allow a repaired flexor tendon to withstand the stresses encountered during early active mobilization. This simple eight-strand technique will be particularly useful to surgeons who commonly employ the cross-lock stitch for primary flexor tendon repair following early mobilization.

References
1.
Xie R, Tang J . Investigation of locking configurations for tendon repair. J Hand Surg Am. 2005; 30(3):461-5. DOI: 10.1016/j.jhsa.2005.02.006. View

2.
Schuind F, Garcia-Elias M, Cooney 3rd W, An K . Flexor tendon forces: in vivo measurements. J Hand Surg Am. 1992; 17(2):291-8. DOI: 10.1016/0363-5023(92)90408-h. View

3.
Wu Y, Mao W, Tang J . The impact of transverse components on 4-strand tendon repairs. J Hand Surg Eur Vol. 2021; 46(8):830-835. DOI: 10.1177/17531934211018309. View

4.
Pennington D . The locking loop tendon suture. Plast Reconstr Surg. 1979; 63(5):648-52. DOI: 10.1097/00006534-197905000-00007. View

5.
Watanabe K, Ota H, Sasaki H . Eight-strand Cross-locked Cruciate Flexor Tendon Repair Using Double-stranded Suture: A Description of the Surgical Technique. Plast Reconstr Surg Glob Open. 2016; 4(11):e1048. PMC: 5142471. DOI: 10.1097/GOX.0000000000001048. View