» Articles » PMID: 36320336

Debridement Versus Simple Scrubbing of External Fixator Pin Sites

Overview
Journal Kans J Med
Specialty General Medicine
Date 2022 Nov 2
PMID 36320336
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Irrigation and debridement of external fixator pin sites are methods utilized by some orthopedic surgeons to minimize the risk of surgical site infections in patients undergoing definitive internal fixation after temporization in an external fixation device. This study aimed to determine if irrigation and debridement of external fixator pin sites leads to fewer deep surgical site infections, compared to simply scrubbing the external fixator pin sites with a chlorhexidine scrub-brush.

Methods: This single center retrospective cohort study was performed at a university level I trauma center. All cases in which a single surgeon removed an external fixator and followed this with definitive open reduction and internal fixation (ORIF) in the same operative setting between October 2007 and October 2018 were reviewed. A total of 313 patients were temporized in 334 external fixators prior to ORIF and were included in the study.

Results: Eighteen of the 179 Irrigation and Debridement cohort (10.0%) and 8 of the 155 Simple Scrubbing cohort (5.2%) had infections that required a return to the operating room. No statistical difference (p = 0.10) or meaningful effect size (Cohen's d = 0.18) were found between irrigation and debridement and simple scrubbing of external fixator pin sites.

Conclusions: Given no significant differences were found in deep infection rates between debridement of pin sites versus simply scrubbing, it is reasonable to ask whether the time and resources required for debriding external fixator pin sites is worthwhile.

Citing Articles

Combination of external fixation using digital six-axis fixator and internal fixation to treat severe complex knee deformity.

Liu S, Yu D, Li H, Opoku M, Li J, Zhang B J Orthop Surg Res. 2023; 18(1):65.

PMID: 36707900 PMC: 9881260. DOI: 10.1186/s13018-023-03530-0.

References
1.
Laible C, Earl-Royal E, Davidovitch R, Walsh M, Egol K . Infection after spanning external fixation for high-energy tibial plateau fractures: is pin site-plate overlap a problem?. J Orthop Trauma. 2011; 26(2):92-7. DOI: 10.1097/BOT.0b013e31821cfb7a. View

2.
Waitman L, Warren J, Manos E, Connolly D . Expressing observations from electronic medical record flowsheets in an i2b2 based clinical data repository to support research and quality improvement. AMIA Annu Symp Proc. 2011; 2011:1454-63. PMC: 3243191. View

3.
Kazmers N, Fragomen A, Rozbruch S . Prevention of pin site infection in external fixation: a review of the literature. Strategies Trauma Limb Reconstr. 2016; 11(2):75-85. PMC: 4960058. DOI: 10.1007/s11751-016-0256-4. View

4.
Novais E, Carry P, Kestel L, Ketterman B, Brusalis C, Sankar W . Does Surgeon Experience Impact the Risk of Complications After Bernese Periacetabular Osteotomy?. Clin Orthop Relat Res. 2016; 475(4):1110-1117. PMC: 5339113. DOI: 10.1007/s11999-016-5010-1. View

5.
Cheadle W . Risk factors for surgical site infection. Surg Infect (Larchmt). 2006; 7 Suppl 1:S7-11. DOI: 10.1089/sur.2006.7.s1-7. View